Minimum Order Quantity | 1 Piece |
Brand | Schneider |
Mounting Type | Flush Mounting, Prefixed HMI |
Voltage Type | DC |
Voltage | 24-250 VDC / 24-240 VAC |
Measuring Range | 0.01- 40 ion |
Phase | Single Phase,Three Phase |
Frequency | 50/60 Hz |
Standard Manufacturers Warranty | 1 years |
Model No | P127 |
Schneider Micom P127 relay is a directional and non-directional overcurrent relay, multifunctional three-phase P127 numerical relay with voltage protection functions.
MiCOM P127 is housed in a compact 4U case in 20TE or 30TE widths, Schneider P127 Relay is fully withdrawable to facilitate easy and quick replacement. The dual-rated current input is powered by conventional 1A or 5A Current Transformers. A wide-range power supply allows a flexible auxiliary voltage to be applied from 24-250Vdc/48-240Vac. P122 also offers a compact case solution with reduced hardware and functionality where installation space is minimal.
Software features include 2 settings groups for quick switching between application configurations and customisable reflex automation, allowing logical AND, OR or NOT gates.
MiCOM P127 devices also include a rear RS485 communication port with a variety of protocols; DNP3, IEC 60870-5-103, Modbus and Courier.
Schneider Micom P127 numerical relay Main Characteristics:range of product | MiCOM P127 | |
device short name | P127 | |
relay application | Feeder | |
protection type | Overcurrent ANSI code: 50/51 Recloser ANSI code: 79 Cold load pick-up Earth fault ANSI code: 50G/51G Lockout ANSI code: 86 Negative sequence overvoltage ANSI code: 47 Undervoltage ANSI code: 27 Overvoltage ANSI code: 59 Rate of change of frequency ANSI code: 81R Neutral voltage displacement ANSI code: 59N Thermal overload protection ANSI code: 49RMS Underfrequency ANSI code: 81L Phase undercurrent ANSI code: 37 Breaker failure ANSI code: 50BF Negative sequence overcurrent ANSI code: 46 Restricted earth fault ANSI code: 64REF Directional earth fault ANSI code: 67N Directional phase overcurrent ANSI code: 67 Overfrequency ANSI code: 81O Voltage-restrained overcurrent ANSI code: 50V/51V | |
number of inputs | 4 current input CT...X/5 A and X/1 A 3 voltage 12 discrete | |
number of outputs | 9 discrete | |
communication port protocol | DNP3 IEC 60870-5-103 Modbus RTU |
[Us] rated supply voltage | 24 250 V DC 19.2 300 V 48 250 V DC 38.4 300 V 48 240 V AC 38.4 264 V | |
control and monitoring type | Circuit breaker/contactor control | |
network and machine diagnosis type | Fault recording Event recording Disturbance recording15 s | |
switchgear diagnosis type | CT/VT supervision Trip circuit supervision ANSI code: TCS | |
display type | Backlit LCD: 2 lines of 16 characters | |
discrete input voltage | 24 250 V DC 19.2 V standard variant 48 250 V AC 19.2 V standard variant 48 250 V DC 105 V further option 48 250 V DC 77 V further option 48 250 V DC 154 V further option 48 240 V AC 105 V further option 48 240 V AC 77 V further option 48 240 V AC 154 V further option | |
communication port support | RS232 RS485 |
Minimum Order Quantity | 1 Piece |
Current Rating | 1A |
Brand | Schneider Electric |
Voltage Type | DC |
Voltage | 24-60 VAC / DC ,90-240 VAC/250 VDC |
Model Name/Number | P111L, P111A , P111E , P1F1L , P1F1A , P1F1E |
Measuring Range | 0.1-40 in ,IN = 1A/5A |
Current | 1-5A |
Model Number | P111 / P1F1 |
Material | Mild Steel |
Phase | 1, 2, or 3-phase arrangement, Single Phase, Two Phase, Three Phase |
Power Source | Electric /AC DC |
Frequency | 50-60Hz |
Schneider Micom P111 Relay is suitable for all applications requiring over-current and/or earth-fault protection.
Due to its cost effectiveness and technical features, the MiCOM P111 relays can be used in both medium and low -voltage applications. Their user-friendly design provides a full set of easily accessible measurements.
MiCOM P111 can be used where communication facilities are required and their many features allow for easy adaptation to different applications and operational conditions.
MiCOM S1 setting software enables easy configuration and access to all measurements. In addition, MODBUS RTU communication protocol allows interfacing with substation control or the SCADA system. MiCOM P111 is housed in a small case for rail or rack mounting.
Cost competitive features enable full measurements
MiCOM P111 provides flexible current relay, a full set of measurements and a wide range of efficient features at a competitive price.
Our catalog of Schneider Micom Protection Relays provides leading and reliable protection and control for any network application. The latest Protection Relays also offer comprehensive security and dependability for your electrical grid, from overcurrent and arc protection to distance and differential protection of the transmission line. Our product range offers solid protection with advanced communications such as the IEC 61850 to give you peace of mind in protecting your grid. Contact us to get Micom P111 price!
The PowerLogic P1 relays are suitable for the applications where overcurrent and/or earthfault and voltage protection are required.
PowerLogic P1F and P1V models can be applied to medium and low voltage electrical systems.
Main Features
The following functions are generally available in all devices:
• Operate in 1, 2, or 3-phase arrangement.
• Two setting groups, selected from the relay menu, binary input or SCADA/DCS.
• Flush mounted case.
• Fundamental and True RMS (within a frequency range from 10Hz to 1kHz) phase
current value measurement.
• 9 button keypad to input settings, configure the relay and close and trip
command and display (graphical).
• Fault record for most recent trips.
The P1F protection relays are comprised of a suite of protection functions as well as
auxiliaries. Each function can be individually configured or disabled to suit every kind
of application.
All available functions, including protection, automation, communication, LEDs,
inputs and outputs, are easily programmable through the user-friendly human
machine interface and/or the eSetup Easergy Pro software interface.
The graphical LCD provides the user with key information (faults, measurements,
settings, etc.). The menus have a pull-down structure for easy use and quick access
to any data. User can switch HMI language directly through the front panel.
8 LEDs (6 freely configurable) indicate the correct operation of the relay as well as
other information regarding the protection of the electrical system.
The hardware architecture and software algorithms have been designed to operate
on very short failure detection times. Tripping occurs typically within 40 ms.
Application
PowerLogic P1F numerical overcurrent protection relay provides an optimized
solution. Typical applications are:
• Utility and industrial substation fitted with cost-optimized MV switchboards
• Retrofit relays of old technology, particularly during installation of DCS systems
• Transformers, incomers, bus couplers, overhead lines and underground cables
on MV systems
• Neutral system protection (insulated, solid and resistance earthed)
• LV substations.
Model Name/Number | P821 |
Brand | Schneider |
Voltage | 110 V |
Current | DC |
Mounting Type | Panel |
Type | Industrial Relay |
Display Type | DIGITAL |
Power Source | Electric |
Frequency | 50 Hz |
Usage/Application | Breaker failure protection |
Display | Digital |
Mounting | Din rail/ panel / wall |
Model No | P821 |
MiCOM P821 is an Advanced Breaker Failure and protection relay based on the latest numerical technology.
MiCOM P821 provides enhanced protection due to the advanced numerical technology used in its design. It is highly reliable and flexible, and can be used with any application.
Wide monitoring capacities for maximum control
MiCOM P821 offers a range of protection functions, combined with extensive monitoring capacities, for optimum efficiency and maximum control of electrical schemes. An enhanced breaker failure protection function provides back up protection when the primary circuit fails to isolate the fault.
While this numerical relay is designed as a phase segregated detection device for EHV/HV/MV levels, it is also flexible enough for all voltage ranges and can be applied to any application.
The MiCOM P821 can use either single-stage breaker failure protection (tBF1) for back up protection to the local circuit breaker, or two-stage breaker failure protection (tBF1 & tBF2).
Reliable detection, easy to program
MiCOM P821 ensures reliable phase segregated detection for 1/3 pole breaker tripping, and is suitable for all voltage levels. It also provides sensitive residual current detection and boast a fast RESET time. Equipped with one or two-stage CB failure, it is easy to program with the standard MiCOM Px20 setting procedure.
*Your information is safe with us.
Model Name/Number | P443 |
Relay Type | Distance protection |
Brand | Schneider |
Type | Industrial Relay |
Color | White |
Usage/Application | Full scheme distance protection |
Schneider Easergy MiCOM P443 protection relay is complemented by various serial and Ethernet communication protocols including IEC61850 and a multi-language HMI featuring English, French, German, Spanish, Russian and Chinese. Protection is further enhanced by the use of Programmable Scheme Logic within the device.
The range offers quadrilateral (polygon) or mho characteristics with a long history of high performance, load blinding areas, comprehensive range of teleprotection schemes, Power swing alarm and blocking and Multishot autoreclosure with check synchronism.
Housed in 40TE, 60TE or 80TE, 4U case sizes, this advanced distance protection range has fault clearance times of 0.7 to 1 cycle depending on model. Easergy MiCOM P441, P442 and P444 operate on Quadrilateral distance characteristics, whereas Easergy MiCOM P443, P445 and P446 offer both Quadrilateral and Mho distance characteristics.
Latest communication protocols & Ethernet Redundancy
Fully Equipped with the latest communications protocols (IEC61850 Ed1 & Ed2 available in the same device, selection by setting).
Maximum availability and reliability of Ethernet communications thanks to the implementation of PRP/HSR standard redundancy protocols with an instantaneous recovery time (0 ms) in case of network failure.
Dual IP address allows the device to be connected to 2 independent communication networks (e.g, SCADA system network & Maintenance network)
Universal IRIG-B input (automatically detects modulated or unmodulated signal)
Major enhancement to Cybersecurity
Operational & Cybersecurity, compliant to IEC 62351, helps protect installations with security based on embedded features such as Role Based Access Control (RBAC), Port Hardening, Security Logs and Access Traceability. The IED by default includes RBAC with different users defined and a Security Administrator.
Proven experience and fastest operating times
Extensive distance protection experience and algorithms using Delta algorithm, Mho and Impedance measurement techniques.
Mho pedigree with over 25 years experience
Wide choice of channel aided scheme
Relay determines its own settings from protected line data (Mho models)
Setting free power swing detection and unblocking for the faults during swings (Mho models)
Our catalog of Schneider Micom Protection Relays provides leading and reliable protection and control for any network application. The latest Protection Relays also offer comprehensive security and dependability for your electrical grid, from overcurrent and arc protection to distance and differential protection of the transmission line. Our product range offers solid protection with advanced communications such as the IEC 61850 to give you peace of mind in protecting your grid.
Brand | Schneider Electric |
Usage/Application | OVERCURRENT PROTECTION |
Range of Product | MiCOM P122 |
Relay Application | Feeder |
Number of Inputs | 4 current input CT...X/5 A and X/1 A |
Number of Outputs | 7 discrete |
Rated Supply Voltage | 24...250 V DC 19.2...300 V |
Type of Measurement | Current |
Height | 177 mm |
Width | 103 mm |
Depth | 270 mm |
Device Mounting | Flush |
Schneider Micom P122 relay is a part of MiCOM P12x range of directional and non-directional overcurrent relays from single phase or earth fault up to the multifunctional three-phase P127 device with voltage protection functions. Models available: MiCOM P120, MiCOM P121, MiCOM P122, MiCOM P123, MiCOM P125, MiCOM P126, MiCOM P127
MiCOM P122 numerical relay is housed in a compact 4U case in 20TE or 30TE widths, MiCOM P12x is fully withdrawable to facilitate easy and quick replacement. The dual-rated current input is powered by conventional 1A or 5A Current Transformers. A wide-range power supply allows a flexible auxiliary voltage to be applied from 24-250Vdc/48-240Vac. P122 also offers a compact case solution with reduced hardware and functionality where installation space is minimal.
Software features include 2 settings groups for quick switching between application configurations and customisable reflex automation, allowing logical AND, OR or NOT gates.
Micom P122 Numerical Relay also includes a rear RS485 communication port with a variety of protocols; DNP3, IEC 60870-5-103, Modbus and Courier.
range of product | MiCOM P122 Numerical Relay | |
device short name | P122 | |
relay application | Feeder | |
protection type | Overcurrent ANSI code: 50/51Cold load pick-up Earth fault ANSI code: 50G/51G Lockout ANSI code: 86 Thermal overload protection ANSI code: 49RMS Phase undercurrent ANSI code: 37 Breaker failure ANSI code: 50BF Negative sequence overcurrent ANSI code: 46 Restricted earth fault ANSI code: 64REF | |
number of inputs | 4 current input CT X/5 A and X/1 A 3 discrete | |
number of outputs | 7 discrete | |
communication port protocol | DNP3 IEC 60870-5-103 Modbus RTU |
DNP3 IEC 60870-5-103 Modbus RTU |
[Us] rated supply voltage | 24 250 V DC 19 300 V 48 250 V DC 38.4 300 V 48 240 V AC 38.4 264 V | |
control and monitoring type | Circuit breaker/contactor control | |
network and machine diagnosis type | Fault recording Event recording Disturbance recording15 s | |
switchgear diagnosis type | CT/VT supervision Trip circuit supervision ANSI code: TCS | |
display type | Backlit LCD: 2 lines of 16 characters | |
discrete input voltage | 24 250 V DC 19.2 V standard variant 48 250 V AC 19.2 V standard variant 48 250 V DC 105 V further option 48 250 V DC 77 V further option 48 250 V DC 154 V further option 48 240 V AC 105 V further option 48 240 V AC 77 V further option 48 240 V AC 154 V further option | |
communication port support | RS232 RS485 | |
Complementary |
Model Name/Number | Micom P120 |
Usage/Application | Overcurrent Relays |
Brand | Schneider |
Voltage | 220 V |
Current | 1 to 5 A |
Model Number | P120 |
Phase | Single Phase |
Frequency | 50/60 Hz |
Schneider Micom P120 relay is a range of directional and non-directional overcurrent relays from single phase or earth fault up to the multifunctional three-phase P127 device with voltage protection functions.
Models available: MiCOM P120, MiCOM P121, MiCOM P122, MiCOM P123, MiCOM P125, MiCOM P126, MiCOM P127
MiCOM P12x is housed in a compact 4U case in 20TE or 30TE widths, MiCOM P12x is fully withdrawable to facilitate easy and quick replacement. The dual-rated current input is powered by conventional 1A or 5A Current Transformers. A wide-range power supply allows a flexible auxiliary voltage to be applied from 24-250Vdc/48-240Vac. P122 also offers a compact case solution with reduced hardware and functionality where installation space is minimal.
Schneider Micom P120 relay features include -2 settings groups for quick switching between application configurations and customizable reflex automation, allowing logical AND, OR or NOT gates.
MiCOM P12x devices also include a rear RS485 communication port with a variety of protocols; DNP3, IEC 60870-5-103, Modbus and Courier.
Mainrange of product | MiCOM P120 | |
---|---|---|
device short name | P120 | |
relay application | Feeder | |
protection type | Lockout ANSI code: 86 Earth fault ANSI code: 50/51 Restricted earth fault ANSI code: 64REF | |
number of inputs | 2 discrete 1 current input CT...X/5 A and X/1 A | |
number of outputs | 5 discrete | |
communication port protocol | IEC 60870-5-103 Modbus RTU DNP3 |
Complementary
[Us] rated supply voltage | 24...250 V DC 19.2…300 V 48...250 V DC 38.4…300 V 48...240 V AC 38.4…264 V | |
---|---|---|
network and machine diagnosis type | Fault recording Event recording Disturbance recording15 s | |
display type | Backlit LCD: 2 lines of 16 characters | |
discrete input voltage | 24...250 V DC 19.2 V standard variant 48...250 V AC 19.2 V standard variant 48...250 V DC 105 V further option 48...250 V DC 77 V further option 48...250 V DC 154 V further option 48...240 V AC 105 V further option 48...240 V AC 77 V further option 48...240 V AC 154 V further option | |
communication port support | RS485 RS232 |
Environment
type of measurement | Current | |
---|---|---|
height | 177 mm total: 157.5 mm embedded: | |
width | 103 mm | |
depth | 270 mm total: 240 mm embedded: | |
device mounting | Flush |
Our catalog of Schneider Micom Protection Relays provides leading and reliable protection and control for any network application.
*Your information is safe with us.
Model Name/Number | P631 |
Brand | Schneider Electric |
Usage/Application | TRANSFORMER PROTECTION |
Relay Type | TRANSFORMER PROTECTION |
Voltage | 220/240 V |
Current | 1 A / 5 A |
Model Number | P63x |
Phase | Single Phase |
Frequency | 50/60 Hz |
Display | Digital |
Mounting | Din rail/ panel / wall |
The MiCOM P63x series differential protection devices are designed for fast, selective, short-circuit protection of transformers, motors, generators and other installations.
Providing quick and selective differential protection, the MiCOM 63x is easily interfaced to almost any kind of substation control or SCADA system. It is user-friendly and provides clear readings from extensive recordings.
High-speed, three-system differential protection
MiCOM P63x provides high-speed three-system differential protection using a triple-slope characteristic and two high-set differential elements in combination with transformer inrush restraint, over fluxing restraint and through-stabilization.
By entering the nominal values of transformer windings and associated CTs, users obtain amplitude and vector group matching. The devices also incorporate many supplementary protective functions. MiCOM P63x provides four setting groups for easy adaptation to varying system operation conditions.
Systems versatility and easy, clear readings
Equipped with 1A/5A setting software, MiCOM P63x has two communication interfaces for SCADA and RTU, and numerous communication protocols. It allows easy and complete device settings and readings from extensive recordings. Available for flush or wall mounting, MiCOM P63x benefits from InterMiCOM interfacing for direct end-end communication between two protection devices.
Model Name/Number | P241 |
Brand | Schneider |
Voltage | DC |
Mounting Type | Flush Mounting |
Type | Industrial Relay |
Current | 5 |
Number Of Poles | 4 |
The Easergy MiCOM P24x versatility provides comprehensive protection for both induction and synchronous machines.
Features enhance power system diagnostics and fault analysis
Easergy MiCOM P24x offers numerous features that ensure complete machine protection. Its comprehensive range of measurement, control and monitoring features enhance power system diagnostics and fault analysis.
Improved machine monitoring and easier maintenance
Easergy MiCOM P24x’s comprehensive protection package includes 87 differential protection and optimization of thermal image monitoring for machines.
These relays not only improve monitoring conditions, but they also facilitate machine maintenance and save on wiring costs.
User Programmable Curve Tool Application Software:Easergy MiCOM P241 – Motor management relay
Easergy MiCOM P242 – Motor management with extended I/O (Digital Inputs and Digital Outputs)
Easergy MiCOM P243 – Motor management, integrated Differential protection with extended I/O and enhanced operator control functions
Housed in standard 40TE, 60TE or 80TE, 4U case sizes, Easergy MiCOM relays offers a complete and scalable range of motor protection with serial and Ethernet communications, including IEC61850 and a multi-language HMI featuring English, French, German, Spanish, Russian and Chinese.
Model Name/Number | P121 |
Brand | Schneider |
Display | Digital |
Rated Supply Voltage | 24...250 V DC 19.2...300 V |
Height | 177 mm |
Width | 103 mm |
Depth | 270 mm |
Device Short Name | P121 |
MiCOM P12x is housed in a compact 4U case in 20TE or 30TE widths, MiCOM P12x is fully withdrawable to facilitate easy and quick replacement. The dual-rated current input is powered by conventional 1A or 5A Current Transformers. A wide-range power supply allows a flexible auxiliary voltage to be applied from 24-250Vdc/48-240Vac. P122 also offers a compact case solution with reduced hardware and functionality where installation space is minimal.
Software features include 2 settings groups for quick switching between application configurations and customisable reflex automation, allowing logical AND, OR or NOT gates.
MiCOM P12x devices also include a rear RS485 communication port with a variety of protocols; DNP3, IEC 60870-5-103, Modbus and Courier.
*Your information is safe with us.
Brand | Schneider |
Mounting Type | Din Rail |
Phase | Single Phase |
Usage/Application | Feeder Management Protection |
Binary Input | 2 |
Output Relay | 8 |
Frequency | 50/60 Hz |
Model No | P13x |
Easergy MiCOM P132 offers a flexible and powerful device housed in a 4U case in 24TE, 40TE or 84TE width. It provides a scalable solution to your needs, for hardware and software. Also includes optional detachable HMI for improved security and safety. Easergy MiCOM P132 offers Bay Control for up to 3 devices and a library of 80 pre-engineered templates to reduce engineering time.
Information exchange is performed by inbuilt communication interfaces, using either serial protocols (IEC 60870-5-101, -103, Courier, DNP or Modbus) or an Ethernet interface using IEC 61850.
In 40TE or 84TE, 4U case sizes, Easergy MiCOM P139 One-Box solution is the most advanced in the range, adding further protection functionality with a graphic LCD display and Bay Control for up to 10 devices, using a pre-engineered library of up to 300 templates.
MiCOM P130C offers a compact case feeder management device with configurable function keys, 17 LED indicators and communication functionality.
Benefits:
Scalable solutions for advanced feeder protection and control
Multifunctional feeder management relay enables the user to cover a wide range of applications in the protection of:
Usage/Application | Motor Protection Relays with RTD Micom |
Brand | Schneider |
Mounting Type | Panel |
Frequency | 50/60 Hz |
Type | Industrial Relay |
Voltage | 220 to 240 V |
Model Number | P225 |
Phase | Single Phase |
Power Source | Electric |
The MiCOM P22x is a range of protection relays designed for motor protection applications. It includes a complete set of protection functions. Not only are they timesaving and cost-effective, but also reliable and increase motor efficiency.
Protection for motor current, voltage and temperature
MiCOM P22x performs a complete set of motor protection functions on current, voltage and temperature measurements. In addition to these basic functions, the relay carries out large number of other functions that enable it to protect and run the motor more effectively. System reliability is further enhanced via checks on bus voltage prior to start-up, supervision of trip-circuit wiring continuity and protection against circuit-breaker failure.
Functions against high inertia loads and anti-backspin ensure that the rotor stops before the motor can be re-started. The MiCOM P22x relay provides a true RMS based thermal image allowing efficient protection against overload phenomena due to the presence of harmonic components.
Comprehensive functions for a large range of applications
The MiCOM P22x series provides comprehensive protection functions for a large range of applications. It is available in both rack and compact design for optimized installation costs. MiCOM P22x improves monitoring conditions, reduces the need for documentation and training, and frees up users’ time.
Model Name/Number | Micom P123 |
Brand | Schneider Electric |
Usage/Application | Overcurrent Protection |
Voltage | 220V |
Current | 1-5A |
Model Number | P123 |
Display Type | Digital |
Phase | Single |
Power Source | Electric |
Schneider Micom P123 Numerical relay is part of MiCOM P12x, a range of directional and non-directional overcurrent relays from single phase or earth fault up to the multifunctional three-phase P127 device with voltage protection functions. Models available: MiCOM P120, MiCOM P121, MiCOM P122, MiCOM P123, MiCOM P125, MiCOM P126, MiCOM P127
MiCOM P123 is housed in a compact 4U case in 20TE or 30TE widths, MiCOM P12x is fully withdrawable to facilitate easy and quick replacement. The dual-rated current input is powered by conventional 1A or 5A Current Transformers. A wide-range power supply allows a flexible auxiliary voltage to be applied from 24-250Vdc/48-240Vac. P122 also offers a compact case solution with reduced hardware and functionality where installation space is minimal.
Software features include 2 settings groups for quick switching between application configurations and customisable reflex automation, allowing logical AND, OR or NOT gates.
MiCOM P123 Numerical relay also includes a rear RS485 communication port with a variety of protocols; DNP3, IEC 60870-5-103, Modbus and Courier.
Main Characteristics: Schneider Micom P123 relayrange of product | MiCOM P123 | |
---|---|---|
device short name | P123 | |
relay application | Feeder | |
protection type | Overcurrent ANSI code: 50/51 Recloser ANSI code: 79 Cold load pick-up Earth fault ANSI code: 50G/51G Lockout ANSI code: 86 Thermal overload protection ANSI code: 49RMS Phase undercurrent ANSI code: 37 Breaker failure ANSI code: 50BF Negative sequence overcurrent ANSI code: 46 Restricted earth fault ANSI code: 64REF | |
number of inputs | 4 current input CT X/5 A and X/1 A 5 discrete | |
number of outputs | 9 discrete | |
communication port protocol | DNP3 Modbus RTU IEC 60870-5-103 | |
[Us] rated supply voltage | 24 250 V DC 19.2 300 V 48 250 V DC 38.4 300 V 48 240 V AC 38.4 264 V | |
---|---|---|
control and monitoring type | Circuit breaker/contactor control | |
network and machine diagnosis type | Fault recording Event recording Disturbance recording15 s | |
switchgear diagnosis type | Trip circuit supervision ANSI code: TCS | |
display type | Backlit LCD: 2 lines of 16 characters | |
discrete input voltage | 24 250 V DC 19.2 V standard variant 48 250 V AC 19.2 V standard variant 48 250 V DC 105 V further option 48 250 V DC 77 V further option 48 250 V DC 154 V further option 48...240 V AC 105 V further option 48 240 V AC 77 V further option 48 240 V AC 154 V further option | |
communication port support | RS232 RS485 |
Environment
type of measurement | Current | |
---|---|---|
height | 177 mm total: 157.5 mm embedded: | |
width | 103 mm | |
depth | 270 mm total: 240 mm embedded: | |
device mounting | Flush |
Discover our catalog of Schneider Micom Protection Relays.
*Your information is safe with us.
Model Name/Number | P841 |
Brand | Schneider |
Voltage | 220-240V |
Usage/Application | Line protection |
Mounting Type | Din Rail |
Model No | P841 |
Type | Industrial Relay |
Single or Three-phase auto-reclosing applications
Easergy Micom P841 Model A can be applied as a stand-alone solution for Auto-reclose and Check synch functionality for feeders controlled by a single circuit breaker.
Easergy Micom P841 Model B can be applied as a stand-alone solution for Auto-reclose and Check synch functionality for Dual circuit breakers applications such as ring bus/mesh corner formations and the breaker-and-a-half configurations.
Latest communication protocols Ethernet Redundancy (coming soon, please contact your local representative for model availability)
Brand | Schneider |
Voltage | 24V-240V |
Mounting Type | Din Rail |
Relay Type | Voltage Relay |
Current | 1A/ 5A |
Application | Feeder management relay |
Easergy MiCOM P14x Feeder Management and Overcurrent Protective Relays are especially suitable where a complete or advanced power system protection scheme solution is required. They include Overcurrent, Earth/Ground Fault and complete protection, advanced communication and integrated functions for feeders. Easergy MiCOM P14x protection relays also offer function keys for integral scheme control functionality.
The following models are available:
Housed in standard MiCOM 40TE, 60TE or 80TE, 4U case sizes, Easergy MiCOM relays offers a complete and scalable range of feeder protection, serial and Ethernet communications, including IEC61850 and a multi-language HMI featuring English, French, German, Spanish, Russian and Chinese.
Model Name/Number | P521 |
Brand | Schneider Electric |
Usage/Application | Feeder Differential Protection |
Phase | Single Phase |
Power Source | Electric |
Frequency | 50/60 Hz |
Model No | P521 |
Body Material | MS |
Schneider MiCOM P521 current differential protection numerical relay provides high speed, two ended current differential unit protection of overhead lines and underground cables in applications such as ring mains and parallel feeders.
MiCOM P521 relay provides fast, efficient current differential protection. It is very flexible and can be applied to a wide range of power systems. Offering a variety of communications interface options, MiCOM P521 differential unit provides valuable local and remote back-up protection.
Multiple interface options and tripping for wide range of power systems
Ensuring optimum phase selection, MiCOM P521's many integrated protection functions allow for application to a wide range of power systems. It offers both local and remote back-up protection. MiCOM P521 also provides fast tripping results for an internal fault, and stability for any out-of-zone fault.
Its many interface options support metallic, direct fiber optic and multiplexed digital links. Tripping uses a proven characteristic comparing differential current with through current, enabling easier testing. MiCOM P521 includes a full range of integrated back-up protection, thereby enhancing reliability.
Highly selective unit protection and value added back-up protection
P521 offers highly selective unit protection and a variety of end-to-end communications interface options. Its numerous integrated back-up elements can run as hot standby in the event of a communications channel outage.
Our catalog of Schneider Micom Protection Relays provides leading and reliable protection and control for any network application. The latest Protection Relays also offer comprehensive security and dependability for your electrical grid, from overcurrent and arc protection to distance and differential protection of the transmission line. Our product range offers solid protection with advanced communications such as the IEC 61850 to give you peace of mind in protecting your grid. Contact us to get more details of the Schneider MiCOM product range of protection relays.
*Your information is safe with us.
Brand | Schneider |
Model No | P547 |
Relay Type | Line Differential |
Type | Industrial Relay |
Model Name/Number | P547 |
Frequency | 50/60 HZ |
Easergy Micom P547 provides optimum protection for EHV and HV lines. With it fast fault clearance times, no external signaling and fully integrated back-up protection functions, it is a cost-effective and highly dependable protection solution.
Simple scheme, additional voltage inputs, fully-integrated back-up protection
Easergy Micom P547's simple protection principle and scheme enables fast fault clearance time. Interfacing with the Power Line Carrier equipment, which operates via the power line, means that the end-to-end scheme communication requires no external signaling channel.
VT inputs may be added to enhance protection stability and sensitivity in long line applications, and where single pole tripping is required. Adding voltage inputs supports distance protection and fault location, and enhances other Easergy Micom P547 functions.
Easergy Micom P547 is equipped with a complete range of fully integrated back-up protection, thereby improving reliability. It also includes sub-cycle distance elements so Easergy Micom P547 can be used in phase comparison scheme applications, for distance applications, or both simultaneously.
Fast fault clearance and no external signaling for cost-effective protection
Easergy Micom P547 provides highly selective unit protection and fast fault clearance times. The power line itself is the signaling medium, and users are not required to depend on VT signals for tripping. Equipped with back-up overcurrent protection, Easergy Micom P547 is a cost-effective alternative to current differential.
Phase | Single Phase |
Model No | P43X |
Power Source | Electric |
Frequency | 50 Hz |
Body Material | MS |
Brand | Schneider |
Voltage | 24V-240V |
Mounting Type | Din Rail |
Relay Type | Voltage Relay |
Current | 1A/ 5A |
Application | Feeder management relay |
Easergy MiCOM P14x Feeder Management and Overcurrent Protective Relays are especially suitable where a complete or advanced power system protection scheme solution is required. They include Overcurrent, Earth/Ground Fault and complete protection, advanced communication and integrated functions for feeders. Easergy MiCOM P14x protection relays also offer function keys for integral scheme control functionality.
The following models are available:
Housed in standard MiCOM 40TE, 60TE or 80TE, 4U case sizes, Easergy MiCOM relays offers a complete and scalable range of feeder protection, serial and Ethernet communications, including IEC61850 and a multi-language HMI featuring English, French, German, Spanish, Russian and Chinese.
*Your information is safe with us.
Voltage Type | DC |
Voltage | 110 DC |
Number of Poles | 4 Poles |
Current | 1 AMP |
Power Source | Electric |
Model No | P740 |
Innovative configuration for centralized or distributed architecture
Easergy Micom P740 ensures security, speed and sensitivity due to its innovative configuration that includes CT saturation detection and dynamic topology processing algorithms. Easergy Micom P740 protection, one of the fastest around (13ms operating time) meets the strict requirements imposed by extra/ultra HV voltage transmission systems.
Easergy Micom P740 busbar differential protection scheme can be engineered to provide a centralized or distributed architecture. It also supports easy busbar maintenance, operation and future expansion.
Fast, adaptable and easy to maintain
Typically operating at 11-15ms, Easergy Micom P740 enables fast fault trips. It can be adapted to any busbar configuration and operates with different types of CT. A high-speed fiber optic cable, which eliminates insulation-related problems, can be used for communications between the Central Unit and the Peripheral Units.
Fully communicant
With the availability of IEC61850-8-1 and IEC103 protocols, the Easergy Micom P740 is easily integrated in any substation system.
Latest communication protocols Ethernet Redundancy (available now in P741)
Fully Equipped with the latest communications protocols (IEC61850 Ed1 Ed2 available in the same device, selection by setting).
Maximum availability and reliability of Ethernet communications thanks to the implementation of PRP/HSR standard redundancy protocols with an instantaneous recovery time (0 ms) in case of network failure.
Dual IP address allows the device to be connected to 2 independent communication networks (e.g, SCADA system network Maintenance network)
Universal IRIG-B input (automatically detects modulated or unmodulated signal)
Major enhancement to Cybersecurity (available soon, please contact your local representative for model availability)
Operational Cyber Security, compliant to IEC 62351, helps protect installations with security based on embedded features such as Role Based Access Control (RBAC), Port Hardening, Security Logs and Access Traceability. The IED by default includes RBAC with different users defined and a Security Administrator.
Benefits:
Voltage | 220 V |
Phase | Single Phase |
Power Source | Electric |
Frequency | 50 Hz |
Model No | Micom 746 |
Easergy MiCOM P746 has proven techniques and dynamic topology processing algorithms, offer a combination of security, speed and sensitivity.
Simple configuration for centralized architecture
The Easergy MiCOM P746 differential busbar protection provides a centralized one box or three boxes architecture and is very simple to use:
It does not need to be deeply engineered and supports easy operation and maintenance of the busbar.
Fast, secure and easy to use
With a typical operating time of 15 ms with High Break High Speed contact option or 19ms with standard contacts, the Easergy MiCOM P746protection is one of the fastest in its class.
Moreover, the trips can be synchronous or sequential, dynamically changing substation topology of the busbar is displayed on any PC with the substation real time dynamic monitoring tool.
Fully communicant
With IEC61850-8.1 Edition 1 or Edition 2, Courier, DNP3.0, Modbus and IEC103 protocols, the Easergy MiCOM P746 is easily integrated in any substation system.
Latest communication protocols Ethernet Redundancy
Fully Equipped with the latest communications protocols (IEC61850 Ed1 Ed2 available in the same device, selection by setting).
Maximum availability and reliability of Ethernet communications thanks to the implementation of PRP/HSR standard redundancy protocols with an instantaneous recovery time (0 ms) in case of network failure.
Dual IP address allows the device to be connected to 2 independent communication networks (e.g, SCADA system network Maintenance network)
Universal IRIG-B input (automatically detects modulated or unmodulated signal)
Major enhancement to Cybersecurity
Operational Cyber Security, compliant to IEC 62351, helps protect installations with security based on embedded features such as Role Based Access Control (RBAC), Port Hardening, Security Logs and Access Traceability. The IED by default includes RBAC with different users defined and a Security Administrator.
Easergy MiCOM P746 REMOTE HMI PC APPLICATION SOFTWARE (Included in MiCOM S1 Studio User Software)
The Easergy MiCOM P746 remote PC HMI allows the user to display the Easergy MiCOM P746 Busbar topology, associated measured analogue quantities and DDB (digital data bus) status information such as circuit breaker and isolator positions and alarms.
Benefits
Model Name/Number | P211 |
Mounting Type | Panel |
Type | Industrial Relay |
Phase | Single Phase |
Power Source | Electric |
Frequency | 50/60 Hz |
Material | MS |
Model No | P211 |
*Your information is safe with us.
Brand | Schneider |
Type | Industrial Relay |
Model Number | P436,P438 |
Current | 1-5 A |
Phase | Single Phase |
Power Source | Electric |
Body Material | MS |
Voltage | 220V |
Current | 1-5A |
Model Number | P138 |
Brand | Micom |
Material | Mild Steel |
Phase | Single |
Power Source | Electric |
Easergy Micom P138, with a proven record of providing comprehensive, efficient protection, can be applied to a wide range of applications. A user-friendly interface and several communication ports allows simple configuration. Highly flexible, Easergy Micom P138 can be customized to the user’s specific requirements.
Independent setting groups and simplified configuration
The Easergy Micom P138 enables a wide range of applications to protect supplies and catenaries in classic and autotransformer-fed (AT) systems. With easy connection to virtually all substation and catenary network management systems, it is enhanced by a complete range of backup protection and automation functions.
Four independent setting groups, with user-friendly control interface, store protection parameters and enable simple configuration to different operating conditions or alternative feeding. Extensive polling of information is also possible.
Easergy Micom P138 also features InterMiCOM teleprotection. Available in a modular design, it can be rack, flush panel or wall surface-mounted.
Flexibility and easy integration
User-friendly Easergy Micom P138is fitted with 1A/5A software setting, both supported in a single device, and two remote communication interfaces. It also benefits from InterMiCOM teleprotection interface. Users can customize the Easergy Micom P138 to their own applications, and its flexibility enables easy integration into various substation protective schemes.
Model Name/Number | P921 |
Brand | Schneider |
Voltage | 220/240 V |
Current | 1 to 5 A |
Model Number | P921 |
Power Source | Electric |
Frequency | 50/60 Hz |
MiCOM P9xx series of voltage and frequency relays are capable of highly versatile applications and are easily integrated into both new and existing network control systems. They offer improved power quality and are an ideal cost effective solution for maintaining system stability.
Versatile applications and enhanced techniques
Their application versatility and association of protection functions with automation, control and measurement make MiCOM P9xx an optimal, innovative solution for ensuring power system stability and maintenance reduction.
By employing enhanced techniques, designed to operate under non-linear abnormalities and sub-oscillations, MiCOM P9xx eliminates the risk of unwanted operations. With up to 30 output contacts, users can create simple or complex load and generation management schemes using the relay's logic capabilities.
Integrated restoration facilities ensure that any disconnected loads are reconnected as soon as possible after system recovery. Industry standard communication protocols permit easier integration into both new and existing network control systems.
*Your information is safe with us.
Relay Type | Frequency Relay |
Voltage | 220/240 V |
Current | 1 to 5 A |
Type | Industrial Relay |
Model Name/Number | P922 |
Model Number | P922 |
Frequency | 50/60 Hz |
Body Material | MS |
MiCOM P9xx series of voltage and frequency relays are capable of highly versatile applications and are easily integrated into both new and existing network control systems. They offer improved power quality and are an ideal cost effective solution for maintaining system stability.
Versatile applications and enhanced techniques
Their application versatility and association of protection functions with automation, control and measurement make MiCOM P9xx an optimal, innovative solution for ensuring power system stability and maintenance reduction.
By employing enhanced techniques, designed to operate under non-linear abnormalities and sub-oscillations, MiCOM P9xx eliminates the risk of unwanted operations. With up to 30 output contacts, users can create simple or complex load and generation management schemes using the relay's logic capabilities.
Integrated restoration facilities ensure that any disconnected loads are reconnected as soon as possible after system recovery. Industry standard communication protocols permit easier integration into both new and existing network control systems.
Brand | Schneider |
Relay Type | Voltage and frequency |
Voltage | 220/240 V |
Model Number | P923 |
Current | 1 to 5 A |
Power Source | Electric |
Frequency | 50/60 Hz |
MiCOM P9xx series of voltage and frequency relays are capable of highly versatile applications and are easily integrated into both new and existing network control systems. They offer improved power quality and are an ideal cost effective solution for maintaining system stability.
Versatile applications and enhanced techniques
Their application versatility and association of protection functions with automation, control and measurement make MiCOM P9xx an optimal, innovative solution for ensuring power system stability and maintenance reduction.
By employing enhanced techniques, designed to operate under non-linear abnormalities and sub-oscillations, MiCOM P9xx eliminates the risk of unwanted operations. With up to 30 output contacts, users can create simple or complex load and generation management schemes using the relay's logic capabilities.
Integrated restoration facilities ensure that any disconnected loads are reconnected as soon as possible after system recovery. Industry standard communication protocols permit easier integration into both new and existing network control systems.
Usage/Application | Motor protection relays |
Mounting | din rail / panel |
Brand | Schneider |
Current | dc |
Mounting Type | Panel |
Relay Type | Motor Protection Relays |
Type | Industrial Relay |
Voltage | 220 V |
Model No | P220 |
Model Name/Number | p220 |
Display Type | digital |
Phase | Single Phase |
Power Source | Electric |
I Deal In | New Only |
*Your information is safe with us.
Brand | Schneider Electric |
Mounting Type | Din Rail |
Voltage | 220 V |
Phase | Single Phase |
Frequency | 50/60 Hz |
Model No | P638 |
Body Material | MS |
Brand | Schneider |
Current | DC |
Mounting Type | Din Rail |
Voltage | 220 V |
Phase | Single Phase |
Power Source | Electric |
Frequency | 50 Hz |
Model No | P849 |
Easergy MiCOM P849 is the digital input and output extension device for the MiCOM range.
Features:
Latest communication protocols Ethernet Redundancy
Major enhancement to Cybersecurity
Operational Cyber Security, compliant to IEC 62351, helps protect installations with security based on embedded features such as Role Based Access Control (RBAC), Port Hardening, Security Logs and Access Traceability. The IED by default includes RBAC with different users defined and a Security Administrator.
Benefits:
Economical solution - Flexible - Easy to use - Reliable
Integration of Easergy MiCOM P849 into the overall power system further fulfils the needs of electrical supply utilities and industrial consumers by providing many short term and long term
benefits.
Direct cost reduction includes:
Indirect cost reduction includes:
Model Name/Number | P543 |
Brand | Schneider Electric |
Usage/Application | Current Differential Protection |
Type | Industrial relays |
PROTOCOL | IEC 61850 |
key benefits | 1.Schneider MiCOM P543 line differential numerical relay is designed for high performance overhead l |
Schneider MiCOM P543 line differential numerical relay is designed for high performance overhead line and cable applications, it interfaces readily with the longitudinal (end to end) communications channels and has optional distance backup protection.
Models available: MiCOM P541, MiCOM P542, MiCOM P543, MiCOM P544, MiCOM P545, MiCOM P546
The MiCOM P541-P546 series provides high-speed current differential unit protection. The P54x is designed for all overhead line and cable applications, as it interfaces readily with the longitudinal (end-end)communications channel between line terminals. The interface options support direct fibre optic, or multiplexed digital links.
Optimum selectivity is assured, as the scheme measures the currents entering and leaving the protected plant item. Instantaneous tripping results for an internal fault, with stability for any out-of-zone fault. Tripping uses a proven characteristic comparing differential current with through current, for ease of testing. Phase differential elements of this type offer consistent detection of solid and resistive faults, with optimum faulted phase selection, tripping, and indication.
A full range of back-up protection is integrated. This enhances the dependability of the protection, as hot-standby elements (such as distance zones and overcurrent) can be brought into service whenever a signalling channel outage may occur.
P543, P546 devices offer resident subcycle distance protection, to complement the powerful suite of main and backup protection already proven within the family. Full scheme, five zone distance protection is adopted from the class-leading MiCOM P443.
The P54x becomes the standard in all HV, EHV and UHV line protection applications, duplicated where dual redundant main protection is demanded. Set any combination of differential, distance, overcurrent, and reclosing, depending on the site needs.
One universal relay type instead of two or more discrete models means reduced spares holding, less training, and lower cost.
Breaker control and monitoring application
The MiCOM P544 & P546 is suitable for the complex installation and feeders controlled by two circuit breakers such as the breaker-and-a-half configurations. While MiCOM P543 & P545 are suitable for feeders controlled by a single circuit breaker.
Our catalog of Schneider Micom Protection Relays provides leading and reliable protection and control for any network application. The latest Protection Relays also offer comprehensive security and dependability for your electrical grid, from overcurrent and arc protection to distance and differential protection of the transmission line. Our product range offers solid protection with advanced communications such as the IEC 61850 to give you peace of mind in protecting your grid.
*Your information is safe with us.
Usage/Application | Transmission protection |
Model Name/Number | P546 |
Relay Type | Current differential protection |
Brand | Schneider |
Mounting Type | Din Rail |
Type | Industrial Relay |
Schneider MiCOM P546 line differential numerical relay is designed for high performance overhead line and cable applications, it interfaces readily with the longitudinal (end to end) communications channels and has optional distance backup protection.
Models available: MiCOM P541, MiCOM P542, MiCOM P543, MiCOM P544, MiCOM P545, MiCOM P546
The MiCOM P541-P546 series provides high-speed current differential unit protection. The P54x is designed for all overhead line and cable applications, as it interfaces readily with the longitudinal (end-end)communications channel between line terminals. The interface options support direct fibre optic, or multiplexed digital links.
Optimum selectivity is assured, as the scheme measures the currents entering and leaving the protected plant item. Instantaneous tripping results for an internal fault, with stability for any out-of-zone fault. Tripping uses a proven characteristic comparing differential current with through current, for ease of testing. Phase differential elements of this type offer consistent detection of solid and resistive faults, with optimum faulted phase selection, tripping, and indication.
A full range of back-up protection is integrated. This enhances the dependability of the protection, as hot-standby elements (such as distance zones and overcurrent) can be brought into service whenever a signalling channel outage may occur.
P543, P546 devices offer resident subcycle distance protection, to complement the powerful suite of main and backup protection already proven within the family. Full scheme, five zone distance protection is adopted from the class-leading MiCOM P443.
The P54x becomes the standard in all HV, EHV and UHV line protection applications, duplicated where dual redundant main protection is demanded. Set any combination of differential, distance, overcurrent, and reclosing, depending on the site needs.
One universal relay type instead of two or more discrete models means reduced spares holding, less training, and lower cost.
Breaker control and monitoring application
The MiCOM P544 & P546 is suitable for the complex installation and feeders controlled by two circuit breakers such as the breaker-and-a-half configurations. While MiCOM P543 & P545 are suitable for feeders controlled by a single circuit breaker.
Our catalog of Schneider Micom Protection Relays provides leading and reliable protection and control for any network application. The latest Protection Relays also offer comprehensive security and dependability for your electrical grid, from overcurrent and arc protection to distance and differential protection of the transmission line. Our product range offers solid protection with advanced communications such as the IEC 61850 to give you peace of mind in protecting your grid.
Brand | Schneider |
Type | Industrial Relay |
Model Name/Number | Micom P435 |
characteristics | 1. Sensitive rotor earth fault protection using low frequency injection method |
characteristics | 2. Graphical programmable scheme logic eases protection scheme creation and avoids the need for exte |
characteristics | 3. Extensive protection for large machines such as pole slipping and 100% stator earth fault protect |
Easergy MiCOM P43x distance protection and One-Box devices are used for selective short circuit, ground fault and overload protection in all kinds of medium, high and extra-high voltage systems. Models available: Easergy MiCOM P433, Easergy MiCOM P435, Easergy MiCOM P437, Easergy MiCOM P439 and MiCOM P430CKey benefits:
Main characteristics:
Easergy MiCOM P43x offers a comprehensive range of protection functions as standard with optional hardware and software features available to satisfy your individual needs. Easergy MiCOM P439 One-Box solution also includes Bay Control up to 10 devices, including a library of more than 300 pre-engineered bay templates, to reduce your engineering time.
Information exchange is performed by inbuilt communication interfaces, using either serial protocols (IEC 60870-5-101, -103, Courier, DNP or Modbus) or an Ethernet interface using IEC 61850.
Easergy MiCOM P43x is scalable and available in modular 4U case sizes of 40TE or 84TE width, suitable for panel, rack or surface mounting. Wiring connections can be made with either ring or pin terminals, depending on preference and security. A detachable HMI is available to increase security and safety of local operation. Alternatively, it is also available in a Compact case MiCOM P430C, with reduced hardware functionality where mounting size is restricted.
Usage/Application | Full Scheme Distance Protection |
Brand | Schneider Electric |
Type | Industrial Relay |
Mounting | Din Rail/ Panel/ Wall Mount |
Relay Type | Distance Protection |
Model Name/Number | Micom P445 |
Easergy MiCOM P44x provides high speed and high performance distance protection for all overhead lines and cable applications and offers a comprehensive range of protection functions as standard. Models available: MiCOM P441, MiCOM P442, MiCOM P443, MiCOM P444, MiCOM P445, MiCOM P446
Features:
Easergy MiCOM P44x is complemented by various serial and Ethernet communication protocols including IEC61850 and a multi-language HMI featuring English, French, German, Spanish, Russian and Chinese. Protection is further enhanced by the use of Programmable Scheme Logic within the device.
The range offers quadrilateral (polygon) or mho characteristics with a long history of high performance, load blinding areas, comprehensive range of teleprotection schemes, Power swing alarm and blocking and Multishot autoreclosure with check synchronism.
Housed in 40TE, 60TE or 80TE, 4U case sizes, this advanced distance protection range has fault clearance times of 0.7 to 1 cycle depending on model. Easergy MiCOM P441, P442 and P444 operate on Quadrilateral distance characteristics, whereas Easergy MiCOM P443, P445 and P446 offer both Quadrilateral and Mho distance characteristics.
Latest communication protocols & Ethernet Redundancy
Fully Equipped with the latest communications protocols (IEC61850 Ed1 & Ed2 available in the same device, selection by setting).
Maximum availability and reliability of Ethernet communications thanks to the implementation of PRP/HSR standard redundancy protocols with an instantaneous recovery time (0 ms) in case of network failure.
Dual IP address allows the device to be connected to 2 independent communication networks (e.g, SCADA system network & Maintenance network)
Universal IRIG-B input (automatically detects modulated or unmodulated signal)
Major enhancement to Cybersecurity
Operational & Cybersecurity, compliant to IEC 62351, helps protect installations with security based on embedded features such as Role Based Access Control (RBAC), Port Hardening, Security Logs and Access Traceability. The IED by default includes RBAC with different users defined and a Security Administrator.
*Your information is safe with us.
Usage/Application | feeder protection |
Model Name/Number | P145 |
Brand | Schneider Electric |
Voltage | 220-240V |
Current | 1A-5A |
Type | Industrial Relay |
Number Of Poles | 2 Pole |
Coil Type | Non Latching |
MiCOM Agile P14x feeder management relays provide an integrated solution for the complete protection, control and monitoring of overhead lines and underground cables, covering all distribution and transmission voltage levels. Providing all essential information to efficiently maintain complex power systems and their components, the P14x relay family is user-friendly and highly flexible, allowing application on any network.
The MiCOM Agile P14x is an advanced feeder management relay platform with overcurrent and earth fault protection, as well as autoreclose and a full suite of protection, control and monitoring functions. The relay can also be used as high impedance busbar with full scheme supervision. The platform also provides main or back-up protection for MV/HV, solidly earthed, impedance earthed, Petersen coil earthed and isolated neutral systems.
Key benefits:
Voltage | 220 V |
Current | 1-5 A |
Model Number | P64x |
Phase | Single Phase |
Power Source | Electric |
Frequency | 50/60 Hz |
Brand | Schneider |
Model No | P342 |
Relay Type | Overload Relay |
Type | Industrial Relay |
The MiCOM generator protection relays provide flexible and reliable integration of protection, control, monitoring and measurement functions.
The wide range of functions offered in this range offer complete protection and control. Their flexibility results in cost-effective solutions for an extensive list of applications.
*Your information is safe with us.
Brand | Schneider |
Relay Type | Generator protection |
Model Name/Number | Micom P345 |
Model Number | P345 |
Brand | Schneider |
Model No | P344 |
Relay Type | Generator Protection Relay |
Type | Industrial Relay |
The MiCOM generator protection relays provide flexible and reliable integration of protection, control, monitoring and measurement functions.
The wide range of functions offered in this range offer complete protection and control. Their flexibility results in cost-effective solutions for an extensive list of applications.
Brand | Schneider |
Relay Type | Voltage Relay |
Type | Industrial Relay |
Easergy MiCOM P14x Feeder Management and Overcurrent Protective Relays are especially suitable where a complete or advanced power system protection scheme solution is required. They include Overcurrent, Earth/Ground Fault and complete protection, advanced communication and integrated functions for feeders. Easergy MiCOM P14x protection relays also offer function keys for integral scheme control functionality.
The following models are available:
Housed in standard MiCOM 40TE, 60TE or 80TE, 4U case sizes, Easergy MiCOM relays offers a complete and scalable range of feeder protection, serial and Ethernet communications, including IEC61850 and a multi-language HMI featuring English, French, German, Spanish, Russian and Chinese.
*Your information is safe with us.
Usage/Application | Feeder Protection & Bay Control Relay |
Brand | Schneider |
Model Name/Number | Micom P139 |
Relay Type | Voltage Relay |
Voltage Type | DC |
Type | Industrial Relay |
Easergy MiCOM P13x is a range of feeder management and One-Box solutions for flexible and comprehensive protection and control of feeders. Models available: Easergy MiCOM P132 and Easergy MiCOM P139