Brand | GE |
Mounting Type | Din Rail |
Relay Type | Distance protection |
Voltage | 220/240 V |
Type | Industrial Relay |
Model Name/Number | MiCOM Agile P441, P442 & P444 |
These distance protection systems are ideal for single circuit breaker application, single and/or 3-pole tripping, and includes a full suite of monitoring, control and recording capabilities plus fault locator, autoreclose and check synchronism.
Key features:
Brand | GE |
Voltage | 220V-240V |
Current | 1A TO 5A |
Power Source | Electric |
Relay Type | Distance protection |
Mounting Type | Panel |
Model Name/Number | P443 |
Part of the MiCOM P40 platform, the Agile P543 Line Differential Protection numerical relay and P544, P545 & P546 range of transmission-class protection relays provide comprehensive line protection for differential, subcycle distance and directional earth fault applications, with 1/3 pole tripping. This range of products is ideal for HV, EHV and UHV applications on lines and cables of any length.
The MiCOM Agile P543 Relay, P544, P545 & P546 range of transmission-class protection relays provide high speed current differential unit protection. They are designed for overhead line and cable applications, interfacing readily with the longitudinal (end-end) communications channel between line terminals. The interface options support direct fiber optic or multiplexed digital links.
Each of the models offer resident subcycle distance protection to complement the powerful suite of main and backup protection. Full scheme, five-zone distance protection is adopted from the class-leading MiCOMho MiCOM Agile P443. The product line becomes the standard in all HV, EHV and UHV line protection applications, duplicated where dual redundant main protection is demanded. Set any combination of differential, distance, overcurrent and reclosing, depending on the site needs. One universal relay type instead of two or more discrete models means reduced spares holding, less training, and lower cost.
The MiCOM Agile P544 and P546 are suitable for the complex installation and feeders controlled by two circuit breakers such as breaker-and-a-half configurations with dual breaker autoreclose logic schemes with synchrocheck for both breakers.
P543 LINE DIFFERENTIAL PROTECTION KEY BENEFITS:• A universal relay that reduces spare holding - apply as a current differential relay, a distance relay, or both
• Neutral differential boosts sensitivity of tripping for resistive earth faults, even for lines with heavy load-flow
• Transient biasing reduces CT knee point dimensioning by typically 25% compared to historical applications
• Differential protection adaptable to all different substation topologies: in-zone transformers and unequal line end CT ratios
GE MiCOM Agile P543 Main characteristics:
• Comprehensive communication options including IEC 61850 Edition 1 and Edition 2
• IEC 61850 redundant Ethernet, supporting self healing ring, RSTP, dual homing, PRP or HSR
• Fast subcycle distance protection with 5 quadrilateral or mho zones and setting free power swing detection
• InterMiCOM64 for transmitting 8 digital signals through teleprotection communication links
P543 Relay Key features:
• Current transformer supervision operates with or without voltage inputs, to prevent any spurious tripping and raise the alarm
• True subcycle distance protection with transmission class security and dependability
• Unparallelled speed, security and selectivity
• Compatible with 56/64kbps or 2Mbps for direct fiber or MUX communications channels
• Suitable for use with equal or unequal transmit and receive path delays (eg SDH/SONET)
• Suitable for MPLS differential channels
• Full suite of monitoring, control and recording capabilities plus fault locator, autoreclose and check synchronism
• Harsh environment coating as standard for all GE’s MiCOM P540 series relays protects against corrosive gases such as H2S or SO2
• No internal batteries in GE-branded models – removes a maintenance item and eases air-freight logistics
• NERC CIP cybersecurity
• Binary inputs ESI48-4 EB2 compliant
Explore GE numerical Relays portfolio with us!
Model Name/Number | GE 489 |
Relay Type | Generator protection |
Brand | GE |
Voltage | 220/240 V |
Current | 1 to 5 A |
Type | Industrial Relay |
The SR489 Generator Protection System, a member of the SR family of relays, provides protection, control and advanced communications in a cost effective industry leading draw-out construction. Designed for small and medium sized generators, the 489 delivers advanced protection including generator stator differential protection. The 489 also includes detailed diagnostic information allowing for reduced troubleshooting time.
Key Benefits
*Your information is safe with us.
Usage/Application | commissioning and fault-finding in electrical plant |
Voltage | 220-240V |
Current | 1A-5A |
Brand | GE |
Mounting | Din rail / panel |
Model Name/Number | P842 |
Relay Type | Distance protection |
Its flexibility means it can be used with different bus-bar arrangements.The MiCOM Agile P842 Mesh Corner Reclose unit (MCU) provides a flexible, distributed scheme for delayed auto-reclose (DAR) and auto-isolation of a mesh bus station.
High-speed peer-peer communications
The MiCOM Agile P842 uses high-speed peer-peer communication facilities over ethernet, and provides for the automatic reclosure of circuit breakers. It also ensures automatic isolation of a persistently faulted plant and suppresses ferro-resonance following a system fault.
The equipment is provided on the basis of one MCU per mesh corner. Although each MCU is an autonomous unit, inter-unit communications guarantees co-ordinated control of a complete mesh system.
Flexibility for easy commissioning and fault-finding
The MiCOM Agile P842 ensures that only the faulted electrical plant is isolated for permanent faults. It provides flexibility for different busbar arrangements, carries out system checks, and suppresses ferro-resonance. MiCOM Agile P842 is equipped with real time peer-peer communications and allows easy commissioning and 'fault-finding'.
About MiCOM P40 Agile
Agile’s philosophy is one of continuous improvement in our products and solutions. Our emphasis on communication in MiCOM has become a focus which secures leadership in the digital substation. To mark this phase of evolution, the brand “P40 Agile” is applied to the range. P40 Agile is a mark of performance and quality, proudly available from Agile, and only from Agile.
Key Benefit
Usage/Application | Stator Ground Protection |
Voltage | 220-240V |
Current | 1A-5A |
Brand | GE |
Type | Industrial Relay |
Mounting | Din rail / panel |
Complete Generator System Protection
Stator ground module works in combination with GE’s Multlin G60 and MiCOM Agile P345 to provide a 100% stator ground fault protection that is operational during generator start-up, running and stopped conditions. In the 100% stator ground fault protection based on sub-harmonic injection, a 20Hz voltage is injected to detect ground faults at any point across 100% of the winding thereby protecting the complete stator winding and allowing early detection of stator ground fault conditions.
Key Benefits
• Detect ground faults through 100% of the stator winding including neutral point
• Sub-harmonic injection based stator ground protection provides early detection of ground fault conditions
• Designed to operate with industry leading G60 and P345 Generator Protection Systems • Active protection of the generator even under machine shutdown conditions for increased asset life
• Providing a wide range of fault resistance coverage which allows for greater generator protection
• Increase generator life span by easily upgrading your current G60 or P345 generator protection relay with the 100% Stator Ground Protection Module
Usage/Application | Generator protection |
Voltage | 220-240V |
Current | 1A-5A |
Brand | GE |
Type | Industrial Relay |
Mounting | Din rail / panel |
The Multilin 889 relay, a member of the Multilin 8 Series protective relay platform, has been designed for the protection, control, monitoring and management generators and in-zone transformers used in both industrial and utilities applications.
The Multilin 889 provides advanced, high-speed protection, extensively customizable programmable logic, and flexible configuration capabilities, to maximize the operational performance and life of critical generators.
Equipped with the latest in advanced communications, the Multilin 8 Series supports IEC 61850 Edition 2 ensuring simplified device integration and dual communication ports with IEC 62439/PRP, enabling users to achieve zero latency in communications for high reliability network architectures, ensuring complete asset monitoring and control.
Key Benefits
*Your information is safe with us.
Usage/Application | protection, control and monitoring of overhead lines and underground cables |
Voltage | 220-240V |
Current | 1A-5A |
Brand | GE |
Type | Industrial Relay |
Frequency | 50 Hz |
Mounting | Din rail / panel |
The MiCOM Agile P841 is a multifunctional line terminal IED for control and back-up protection in transmission and sub-transmission feeder bays. The P841 provides management of single or dual breaker autoreclose logic schemes with synchrocheck.
Key features:
Models:
What''s New
Enhanced Ethernet board module with switchable Ethernet redundancy delivered in a single model.
The new board module is supported on P841 SW 76, 79 and 86.
It supports PRP, HSR and RSTP in one model, allowing a single P40 model to be used in any application requiring redundant Ethernet communications. The new module is designed to handle high density traffic in the IEC 61850-8-1 network, with time latency halved. Larger architecture digital substations can also be supported, with up to 50 nodes now possible in HSR rings.
Key Features & Benefits:
• Providing advanced field ground fault protection for generator applications
• Allowing both single point and double point injection methods provides optimal application flexibility depending on system configuration
• Reduce generator down-time by locating the fault within the field winding when connected in single point injection method
• Designed to operate with Multilin’s industry leading G60 Generator Protection System • Continuously monitors and protects the generator during stopped, starting and running conditions for increased asset life
• Reduce system configuration time by configuring the Field Ground Protection Module through the G60 Generator Protection System and the easy-to-use EnerVista Setup Software
• Increase generator life span by easily upgrading your current G60 generator protection relay with the Field Ground Protection Module
Usage/Application | phase comparison line protection including unit protection, subcycle distance and directional earth |
Voltage | 220-240V |
Current | 1A-5A |
Brand | GE |
Type | Industrial Relay |
Mounting | Din rail / panel |
MiCOM Agile P547 phase comparison relay provides comprehensive phase comparison line protection including unit protection, subcycle distance and directional earth fault (DEF) for single and three pole tripping applications. It is adapted to two and three-terminal lines, and lines with transformer tee-off feeds.
· Interfacing with the Power Line Carrier equipment, which operates via the power line, means that the end-to-end scheme communication requires no external signaling channel. VT inputs may be added to enhance protection stability and sensitivity in long line applications, and where single pole tripping is required. Adding voltage inputs supports distance protection and fault location and enhances other MiCOM Agile P547 functions.
Key features:
· Distance to fault location assists dispatching of maintenance crews
· Graphical programmable scheme logic eases protection scheme creation, and avoids the need for external logic controllers
· IEC 61850 redundant Ethernet, supporting self healing ring, RSTP, dual homing, PRP or HSR
· Optional mho and quadrilaterial subcycle distance protection
· Full suite of monitoring, control and recording capabilities plus fault locator, autoreclose and check synchronism
· Harsh environment coating as standard to all MiCOM relay to protect against corrosive gases such as H2S or SO2
Main characteristics:
· Highly selective unit protection
· Cost effective alternative to current differential
· The signaling medium is the power line itself - fully within the maintenance and operational control of the utility, no external communications dependence
· Advanced charging current compensation and angle-shifting to avoid corona issues - design features to target long-line transmission applications
· Adaptive mixing of sequence components boosts earth fault sensitivity without compromising detection of phase-phase and three-phase faults
Usage/Application | protection, control and monitoring of overhead lines and underground cables |
Voltage | 220-240V |
Current | 1A-5A |
Brand | GE |
Type | Industrial Relay |
Mounting | Din rail / panel |
MiCOM Agile P14x feeder management relays provide an integrated solution for the complete protection, control and monitoring of overhead lines and underground cables, covering all distribution and transmission voltage levels. Providing all essential information to efficiently maintain complex power systems and their components, the P14x relay family is user-friendly and highly flexible, allowing application on any network.
The MiCOM Agile P14x is an advanced feeder management relay platform with overcurrent and earth fault protection, as well as autoreclose and a full suite of protection, control and monitoring functions. The relay can also be used as high impedance busbar with full scheme supervision. The platform also provides main or back-up protection for MV/HV, solidly earthed, impedance earthed, Petersen coil earthed and isolated neutral systems.
Key benefits:
*Your information is safe with us.
Brand | GE |
Relay Type | transformer protection |
Model Name/Number | P642 |
Current | dc |
Display | Digital |
Mounting | Din rail/ panel / wall |
Transformers are high capital assets in electrical power systems. Elimination of all electrical and mechanical stresses, although desirable to preserve transformer life, is impractical. Adaptive techniques to measure, alarm (or trip) and advise on cumulative service can help to schedule preventive maintenance before a costly failure occurs. Internal faults are a risk for all transformers, with short-circuits dissipating the highest localized energy. Unless cleared quickly, the possibility to rewind windings reduces and core damage may become irreparable.
GE's P642, P643 and P645 address all these issues, preserving service life and offering fast protection for transformer faults. A transient bias technique has been included, enhancing relay stability and CT requirements. Hosted on an advanced IED platform, the P64x incorporates differential, REF, thermal, and overfluxing protection, plus backup protection for uncleared external faults. Model variants cover two and three-winding transformers (including auto-transformers), with up to five sets of 3-phase CT inputs.
Key benefits:
Main characteristics:
Model Name/Number | P741 |
Brand | Schneider Electric |
Usage/Application | Busbar protection relay |
Current | dc |
Order Code | p741 |
Type | Industrial relays |
Display | Digital |
The MiCOM Agile P74x offers high performance, secure and sensitive protection for all types of busbar configurations at all voltage levels. Consisting of the Agile P741, P742 and P743 relays, the P74x platform is engineered to provide a centralized or distributed architecture with CT saturation detection, dynamic topology processing algorithms and a fast reset (less than 1 cycle) circuit breaker failure element.
Key benefits:
Key benefits:
Usage/Application | Generator protection |
Voltage | 220-240V |
Current | 1A-5A |
Brand | GE |
Type | Industrial Relay |
Mounting | Din rail / panel |
GE's Agile P34x generator protection solutions provide extensive functionality to meet all generator and generator - transformer applications, including differential protection for fast and selective tripping of phase and earth faults. All generator protection, control, monitoring, recording and communications components are housed within one box, and the solutions are accompanied by a comprehensive library of hardware options, protection and control functions to meet system requirements.
Key benefits:
Main characteristics:
*Your information is safe with us.
Brand | Schneider |
Current | dc |
Mounting Type | Panel |
Type | Current Relay |
Model Name/Number | P544 |
Display Type | Digital |
The MiCOM Agile P543, P544, P545 & P546 range of transmission-class protection relays provide high speed current differential unit protection. They are designed for overhead line and cable applications, interfacing readily with the longitudinal (end-end) communications channel between line terminals. The interface options support direct fiber optic or multiplexed digital links.
Each of the models offer resident subcycle distance protection to complement the powerful suite of main and backup protection. Full scheme, five-zone distance protection is adopted from the class-leading MiCOMho MiCOM Agile P443. The product line becomes the standard in all HV, EHV and UHV line protection applications, duplicated where dual redundant main protection is demanded. Set any combination of differential, distance, overcurrent and reclosing, depending on the site needs. One universal relay type instead of two or more discrete models means reduced spares holding, less training, and lower cost.
The MiCOM Agile P544 and P546 are suitable for the complex installation and feeders controlled by two circuit breakers such as breaker-and-a-half configurations with dual breaker autoreclose logic schemes with synchrocheck for both breakers.
Key benefits:
Main characteristics:
Model Name/Number | P545 |
Brand | Schneider Electric |
Usage/Application | Current Differential Protection |
Type | Current relays |
Display | Digital |
The MiCOM Agile P543, P544, P545 & P546 range of transmission-class protection relays provide high speed current differential unit protection. They are designed for overhead line and cable applications, interfacing readily with the longitudinal (end-end) communications channel between line terminals. The interface options support direct fiber optic or multiplexed digital links.
Each of the models offer resident subcycle distance protection to complement the powerful suite of main and backup protection. Full scheme, five-zone distance protection is adopted from the class-leading MiCOMho MiCOM Agile P443. The product line becomes the standard in all HV, EHV and UHV line protection applications, duplicated where dual redundant main protection is demanded. Set any combination of differential, distance, overcurrent and reclosing, depending on the site needs. One universal relay type instead of two or more discrete models means reduced spares holding, less training, and lower cost.
The MiCOM Agile P544 and P546 are suitable for the complex installation and feeders controlled by two circuit breakers such as breaker-and-a-half configurations with dual breaker autoreclose logic schemes with synchrocheck for both breakers.
Key benefits:
Main characteristics:
Model Name/Number | P645 |
Relay Type | Overload Relay |
Brand | GE |
Voltage | 24V-240V |
Current | 1 to 5 A |
Number Of Poles | 2 |
Transformers are high capital assets in electrical power systems. Elimination of all electrical and mechanical stresses, although desirable to preserve transformer life, is impractical. Adaptive techniques to measure, alarm (or trip) and advise on cumulative service can help to schedule preventive maintenance before a costly failure occurs. Internal faults are a risk for all transformers, with short-circuits dissipating the highest localized energy. Unless cleared quickly, the possibility to rewind windings reduces and core damage may become irreparable.
GE's P642, P643 and P645 address all these issues, preserving service life and offering fast protection for transformer faults. A transient bias technique has been included, enhancing relay stability and CT requirements. Hosted on an advanced IED platform, the P64x incorporates differential, REF, thermal, and overfluxing protection, plus backup protection for uncleared external faults. Model variants cover two and three-winding transformers (including auto-transformers), with up to five sets of 3-phase CT inputs.
Key benefits:
Main characteristics:
*Your information is safe with us.
Model Name/Number | P346 |
Relay Type | Overload Relay |
Brand | GE |
Voltage | 220/240 V |
Current | 1 to 5 A |
Type | Industrial Relay |
Usage/Application | Generator Protection Relay |
PROTOCOL | MODBUS,DNP3,IEC 60870-5-103 and IEC 61850 |
GE''''s Agile P346 generator protection solutions provide extensive functionality to meet all generator and generator - transformer applications, including differential protection for fast and selective tripping of phase and earth faults. All generator protection, control, monitoring, recording and communications components are housed within one box, and the solutions are accompanied by a comprehensive library of hardware options, protection and control functions to meet system requirements.
GE Micom Agile P346 Key benefits:
Alstom P346 Numerical Relays Main characteristics:
We offer Micom Alstom P346 relay and GEs century long tradition of power system innovation. From generators to transmission lines, to motors and beyond, we ensure dependable, safe power worldwide. GE offers a wide range of single function and auxiliary relays, along with a portfolio of accessories, to support high performing and reliable protection and control systems. Explore GE numerical Relays portfolio with us!
Model Name/Number | P348 |
Relay Type | Voltage Relay |
Brand | GE |
Voltage | 24V-240V |
Current | 1 to 5 A |
Usage/Application | Overcurrent protection |
Frequency | 50/60 Hz |
Mounting | Flush |
GE's Agile P34x generator protection solutions provide extensive functionality to meet all generator and generator - transformer applications, including differential protection for fast and selective tripping of phase and earth faults. All generator protection, control, monitoring, recording and communications components are housed within one box, and the solutions are accompanied by a comprehensive library of hardware options, protection and control functions to meet system requirements.
Key benefits:
Main characteristics:
Model Name/Number | P342 |
Relay Type | Voltage Relay |
Brand | GE |
Voltage | 24V-240V |
Current | 1 to 5 A |
Number Of Poles | 2 |
GE's Agile P34x generator protection solutions provide extensive functionality to meet all generator and generator - transformer applications, including differential protection for fast and selective tripping of phase and earth faults. All generator protection, control, monitoring, recording and communications components are housed within one box, and the solutions are accompanied by a comprehensive library of hardware options, protection and control functions to meet system requirements.
Key benefits:
Main characteristics:
*Your information is safe with us.
Usage/Application | Feeder protection relays |
Voltage | 220-240V |
Current | 1A-5A |
Brand | GE |
Number Of Poles | 2 Pole |
Frequency | 50 Hz |
Mounting | Din rail / panel |
Key Features
Protection & Control
The P14N non-directional feeder, P14D directional feeder and P94V voltage and frequency IEDs bring the design rigor and technology of transmission applications to the entire utility and industrial market. P40 Agile IEDs provide an integrated solution for the complete protection, control and monitoring of electrical power systems. Application for overhead lines, underground cables, busbars, breakers, transformers, reactors and distributed generation is supported, right from distribution (as primary protection) to transmission voltage levels (as back-up). The IEDs are suitable for a wide variety of applications in solidly-earthed, resistance- earthed and Petersen coil systems alike.
Powerful graphical logic allows the user to customise the protection and control functions. It is also used to program the optically isolated inputs, relay outputs and LEDs. The logic includes OR, AND and majority gates, timers, and set/reset latch functions, with the ability to invert the inputs and outputs, and provide feedback. The relay has 32 PSL timers could be conveniently configured in PSL, setting or from the relay front panel. The PSL imposes no delay on logic throughput, using concurrent processing being used instead of sequential equations and avoiding any logic ‘race’ issues.
P14D Functional Block Diagram
Model Name/Number | P391 |
Relay Type | Voltage Relay |
Brand | GE |
Voltage | 24V-240V |
Current | 1 to 5 A |
Frequency | 50 Hz |
Mounting | Flush |
The P391 rotor earth fault module provides detection of rotor earth fault faults in the field winding of the generator with the P342-6 generator protection relays. GE's Agile P34x generator protection solutions provide extensive functionality to meet all generator and generator - transformer applications, including differential protection for fast and selective tripping of phase and earth faults. All generator protection, control, monitoring, recording and communications components are housed within one box, and the solutions are accompanied by a comprehensive library of hardware options, protection and control functions to meet system requirements.
Key benefits:
Main characteristics:
Model Name/Number | P543,P544,P545 & P546 |
Brand | GE |
Usage/Application | LINE DIFFERENTIAL AND DISTANCE PROTECTION |
Voltage | 220-240V |
Number Of Poles | 3 Pole |
Type | Industrial relays |
PROTOCOL | IEC 61850 Edition 1 and Edition 2 |
Part of the MiCOM P40 platform, the Agile P543 Line Differential Protection numerical relay and P544, P545 & P546 range of transmission-class protection relays provide comprehensive line protection for differential, subcycle distance and directional earth fault applications, with 1/3 pole tripping. This range of products is ideal for HV, EHV and UHV applications on lines and cables of any length.
The MiCOM Agile P543 Relay, P544, P545 & P546 range of transmission-class protection relays provide high speed current differential unit protection. They are designed for overhead line and cable applications, interfacing readily with the longitudinal (end-end) communications channel between line terminals. The interface options support direct fiber optic or multiplexed digital links.
Each of the models offer resident subcycle distance protection to complement the powerful suite of main and backup protection. Full scheme, five-zone distance protection is adopted from the class-leading MiCOMho MiCOM Agile P443. The product line becomes the standard in all HV, EHV and UHV line protection applications, duplicated where dual redundant main protection is demanded. Set any combination of differential, distance, overcurrent and reclosing, depending on the site needs. One universal relay type instead of two or more discrete models means reduced spares holding, less training, and lower cost.
The MiCOM Agile P544 and P546 are suitable for the complex installation and feeders controlled by two circuit breakers such as breaker-and-a-half configurations with dual breaker autoreclose logic schemes with synchrocheck for both breakers.
P543 LINE DIFFERENTIAL PROTECTION KEY BENEFITS: A universal relay that reduces spare holding - apply as a current differential relay, a distance relay, or both
Neutral differential boosts sensitivity of tripping for resistive earth faults, even for lines with heavy load-flow
Transient biasing reduces CT knee point dimensioning by typically 25% compared to historical applications
Differential protection adaptable to all different substation topologies: in-zone transformers and unequal line end CT ratios
GE MiCOM Agile P543 Main characteristics:
Comprehensive communication options including IEC 61850 Edition 1 and Edition 2
IEC 61850 redundant Ethernet, supporting self healing ring, RSTP, dual homing, PRP or HSR
Fast subcycle distance protection with 5 quadrilateral or mho zones and setting free power swing detection
InterMiCOM64 for transmitting 8 digital signals through teleprotection communication links
P543 Relay Key features:
Current transformer supervision operates with or without voltage inputs, to prevent any spurious tripping and raise the alarm
True subcycle distance protection with transmission class security and dependability
Unparallelled speed, security and selectivity
Compatible with 56/64kbps or 2Mbps for direct fiber or MUX communications channels
Suitable for use with equal or unequal transmit and receive path delays (eg SDH/SONET)
Suitable for MPLS differential channels
Full suite of monitoring, control and recording capabilities plus fault locator, autoreclose and check synchronism
Harsh environment coating as standard for all GEs MiCOM P540 series relays protects against corrosive gases such as H2S or SO2
No internal batteries in GE-branded models removes a maintenance item and eases air-freight logistics
NERC CIP cybersecurity
Binary inputs ESI48-4 EB2 compliant
Explore GE numerical Relays portfolio with us!
*Your information is safe with us.
Usage/Application | Busbar Protection |
Voltage | 220-240V |
Current | 1A-5A |
Brand | GE |
Type | Industrial Relay |
Mounting | Din rail / panel |
The MiCOM Agile P747 provides complete protection for voltage levels up to extra high voltage busbar configurations with a centralized 3-box architecture. The MiCOM Agile P747 can accommodate up to 4 zones plus check zone and protect up to 18 terminals. The MiCOM Agile P747 Is particularly useful in double busbar with double bus coupler applications and allows a high number of opto inputs, relay outputs, and virtual inputs and outputs to manage the complete substation scheme.
The MiCOM Agile P747 also incorporates enhanced circuit breaker failure logic with additional protection functions such as dead zone and overcurrent. In addition, the MiCOM Agile P747 provides a wide range of measurement, monitoring, post fault analysis and self-diagnostic features. Powerful programmable scheme logic, trip circuit supervision, fully customizable menu texts, multi-level password protection, on-line measurements and plant status monitoring are all included. MiCOM Agile P747 employs an innovative external fault detection algorithm to ensure stability when CTs become saturated.
Key benefits:
Model Name/Number | P742 |
Brand | Schneider Electric |
Relay Type | Busbar protection |
Current | DC |
Order Code | p742 |
Display | Digital |
Mounting | Din rail/ panel / wall |
The MiCOM Agile P74x offers high performance, secure and sensitive protection for all types of busbar configurations at all voltage levels. Consisting of the Agile P741, P742 and P743 relays, the P74x platform is engineered to provide a centralized or distributed architecture with CT saturation detection, dynamic topology processing algorithms and a fast reset (less than 1 cycle) circuit breaker failure element.
Key benefits:
Key benefits:
Model Name/Number | P541 |
Brand | GE |
Voltage | 220-240V |
Usage/Application | Line protection |
Coil Type | Non Latching |
Number Of Poles | 2 Pole |
The MiCOM Agile P541 & P542 series provide high speed current differential unit protection. They are designed for overhead line and cable applications, interfacing readily with the longitudinal (end-end) communications channel between line terminals. The interface options support direct fiber optic or multiplexed digital links.
Key features:
Main characteristics:
*Your information is safe with us.
Model Name/Number | P746 |
Brand | Schneider |
Current | DC |
Mounting Type | flush |
Type | Industrial Relay |
Display Type | DIGITAL |
The MiCOM Agile P746 provides complete protection for MV and HV busbar configurations with up to 2 zones plus a check zone and up to 18 terminals. The MiCOM Agile P746 provides a centralized one box or three box architecture and is very simple to use, as it does not need to be deeply engineered and supports easy operation and maintenance of busbars.
The MiCOM Agile P746 protects voltage levels up to extra-high voltage busbar configurations. Proven techniques and dynamic topology processing algorithms offer a combination of security, speed and sensitivity, with simple configuration for centralized architectures.
Key benefits:
Model Name/Number | P743 |
Brand | Schneider Electric |
Usage/Application | Differential Busbar Protection |
Current | DC |
Order Code | P743 |
Type | Industrial relays |
Display | DIGITAL |
The MiCOM Agile P74x offers high performance, secure and sensitive protection for all types of busbar configurations at all voltage levels. Consisting of the Agile P741, P742 and P743 relays, the P74x platform is engineered to provide a centralized or distributed architecture with CT saturation detection, dynamic topology processing algorithms and a fast reset (less than 1 cycle) circuit breaker failure element.
Key benefits:
Key benefits:
Rated Current | DC |
Type | Industrial |
Brand | GE |
Display | Graphical |
Model No | W650 |
Application | generator controller specially adapted to wind turbine generators. |
*Your information is safe with us.
Voltage | 220-240v |
Number Of Poles | 3 Pole |
Dealer of ALSTOM GE MiCOM Agile P54A, P54B, P54C & P54E Multi-Ended Line Differential Protection Relays-Alstom-GE Transmission distance Protection Relay, GE Cable Differential Protection Relay, ALSTOM-GE Line differential Protection Relay, Supplier of Micom Line Differential Protection Relays in India-
The MiCOM P54A/B/C/E range is designed for overhead line and cable applications up to 6 terminals, interfacing readily with the longitudinal (end-to-end) communications channel between line terminals. Previously, transmission and distribution circuits would have two or three ends only, whereas five or more ends are becoming common to connect renewable generation. All models are ready for protection topologies ranging from two to six terminals, whether those multi-terminals exist now, or are provisioned for connection in the future.
Multi-ended current differential protection uses a high-speed and innovative biased differential characteristic. Phase-segregated differential elements provide consistent detection of solid and resistive faults.
Brand | Schneider |
Relay Type | Voltage Relay |
MiCOM Agile P14x feeder management relays provide an integrated solution for the complete protection, control and monitoring of overhead lines and underground cables, covering all distribution and transmission voltage levels. Providing all essential information to efficiently maintain complex power systems and their components, the P14x relay family is user-friendly and highly flexible, allowing application on any network.
The MiCOM Agile P14x is an advanced feeder management relay platform with overcurrent and earth fault protection, as well as autoreclose and a full suite of protection, control and monitoring functions. The platform also provides main or back-up protection for MV/HV, solidly earthed, impedance earthed, Petersen coil earthed and isolated neutral systems.
Key benefits:
Model Name/Number | 489GE |
Relay Type | ELECTRIC RELAY |
Brand | GE |
Voltage | 24 Volts/hz |
Current | 32 Directional power |
Power Source | Refer pdf document |
Mounting Type | Panel |
Type | Industrial Relay |
This product is under last-time buy. Orders may be placed until 31st December 2021, and will be fulfilled based upon availability. As an alternative, please refer to the 889 relay.
The SR489 Generator Protection System, a member of the SR family of relays, provides protection, control and advanced communications in a cost effective industry leading draw-out construction. Designed for small and medium sized generators, the 489 delivers advanced protection including generator stator differential protection. The 489 also includes detailed diagnostic information allowing for reduced troubleshooting time.
Key Benefits
Complete, secure protection of small to medium sized generators
Easy to use generator protection supported by industry leading software tools.
Advanced protection and monitoring features including the use of RTDs for stator and bearing thermal protection and Analog Inputs for vibration monitoring
Draw-out construction allowing for minimized downtime and easy removal/installation of the 489 during maintenance routines
Large, user-friendly front panel interface
Enhanced generator troubleshooting through the use of IRIG-B time synchronized event records, waveform capturing, and data loggers
Simplified setpoint verification testing using built in waveform simulation functionality
Cost effective communication through industry standard hardware (RS232, RS485, 10BaseT Ethernet) and protocols (Modbus RTU, Modbus TCP/IP, DNP 3.0)
Harsh Chemical Environment Option
*Your information is safe with us.
Minimum Order Quantity | 1 Piece |
Model Name/Number | G650 |
Relay Type | Current relay |
Brand | GE |
Voltage | Refer PDF |
Current | Refer PDF |
Number Of Poles | Refer document |
Material | Refer Document |
Usage/Application | Generator protection |
Mounting | Panel |
The G650 is a Distributed Generation Protection and Control Relay designed for complete protection of small to medium sized generators as well as operate as a control system for distributed generation interconnections. The G650 provides a cost effective and scalable solution that allows for tailoring your protection, communications, and I/O requirements to meet the needs of your specific application.
Features and Benefits
Ideal for Distributed Generator Applications
All required protection features for small to medium sized generators
Configurable logic for creating customized generator control schemes
Cost Effective and Scalable Solution
Basic and Enhanced Protection Options
Alphanumeric and Graphical User Interfaces
Multiple Communication options available
Industry Leading Fault Recording Capability
Large capacity Sequence of Event Recording
High Sample Waveform Fault recording (64 samples/cycle)
Long term Data Logger recording
Most features available in the Distributed Generation Protection market segment
Programmable Control Logic
Ethernet Communications
High End Fault Recording
The G650 is a Distributed Generation Protection and Control Relay designed for complete protection of small to medium sized generators as well as operate as a control system for distributed generation interconnections. The G650 provides a cost effective and scalable solution that allows for tailoring your protection, communications, and I/O requirements to meet the needs of your specific application.
Features and Benefits
Ideal for Distributed Generator Applications
All required protection features for small to medium sized generators
Configurable logic for creating customized generator control schemes
Cost Effective and Scalable Solution
Basic and Enhanced Protection Options
Alphanumeric and Graphical User Interfaces
Multiple Communication options available
Industry Leading Fault Recording Capability
Large capacity Sequence of Event Recording
High Sample Waveform Fault recording (64 samples/cycle)
Long term Data Logger recording
Most features available in the Distributed Generation Protection market segment
Programmable Control Logic
Ethernet Communications
High End Fault Recording
Usage/Application | Generator protection |
Voltage | 220-240V |
Current | 1A-5A |
Brand | GE |
Type | Industrial Relay |
Mounting | Din rail / panel |
Built on the industry-leading UR platform, the G30 provides advanced protection for small to medium-sized steam, hydraulic and combustion-turbine generators. The G30 is also well suited for applications where both the generator and transformer are in the same zone of protection, providing the required protection in one device. The G30 provides advanced communication with an integrated managed Ethernet switch, while supporting standard communication protocols including IEC 61850.
Key Benefits
Usage/Application | Generator protection |
Voltage | 220-240V |
Current | 1A-5A |
Brand | GE |
Type | Industrial Relay |
Mounting | Din rail / panel |
Built on the industry-leading UR platform, the G60 offers superior protection for medium and large generators, including large steam and combustion turbines, combined cycle generators and multi-circuit hydro units. The G60 may also be used on pumped storage generators without the need to switch the CT secondary circuitry. The G60 provides advanced communication with an integrated, fully managed Ethernet switch reducing network installation costs while supporting industry standard communication protocols.
Key Benefits
*Your information is safe with us.
Brand | GE |
Display | Graphical |
Model Number | P847 |
Type | Industrial Relay |
Application | To measure power system data in real time and report to the PDC |
Configurations | 3 CT/3 VT, 6 CT/6 VT or 12 CT/6 VT |
The P847 Phasor Measurement Unit forms part of GE’s system monitoring and control. The devices is used to measure power system data in real time and report to the PDC (Phasor Data Concentrator) for visualization, data storage and most importantly for running a variety of ‘on line’ and ‘off line’ applications in systems analysis and control. The ultimate goal is to run the system economically and preserve system stability following major disturbances.
The P847 is GPS synchronized externally through a fiber-optic input (1PPS) and connected to an accurate IRIG-B source (the P594). The PMU function is designed to support IEEE C37.118 – 2011 (2014 amendment) with enhanced performance under off-nominal and dynamic system conditions due to an advanced frequency tracking algorithm.
Basic description:
Overall differentiation factors:
Key customer benefits:
Main characteristics:
Rated Current | DC |
Rated Voltage | 220-240V |
Brand | GE |
Display | Graphical |
Mounting type | Din Rail / panel |
Type | Industrial Relay |
The KVGC202 can be integrated into an overall protection and control system by utilising its integral serial communications, thereby providing information for day-to-day management of power systems.
Key benefits:
Type | Passive RFID |
Size | Small |
Brand | Jonson |
*Your information is safe with us.
Capacity | 2-4 Tons |
Industry | Packaging |
Power Source | AC |
Key Features
Protection & Control
The P14N non-directional feeder, P14D directional feeder and P94V voltage and frequency IEDs bring the design rigor and technology of transmission applications to the entire utility and industrial market. P40 Agile IEDs provide an integrated solution for the complete protection, control and monitoring of electrical power systems. Application for overhead lines, underground cables, busbars, breakers, transformers, reactors and distributed generation is supported, right from distribution (as primary protection) to transmission voltage levels (as back-up). The IEDs are suitable for a wide variety of applications in solidly-earthed, resistance- earthed and Petersen coil systems alike.
Powerful graphical logic allows the user to customise the protection and control functions. It is also used to program the optically isolated inputs, relay outputs and LEDs. The logic includes OR, AND and majority gates, timers, and set/reset latch functions, with the ability to invert the inputs and outputs, and provide feedback. The relay has 32 PSL timers could be conveniently configured in PSL, setting or from the relay front panel. The PSL imposes no delay on logic throughput, using concurrent processing being used instead of sequential equations and avoiding any logic ‘race’ issues.
P14D Functional Block Diagram