Leading Manufacturer of power system studies services consultant and service provider, load flow study, system harmonics study, relay coordination study, system transient stability analysis motor starting and short circuit study from Navi Mumbai.
Request CallBack
  • Power System Studies Services Consultant And Service Provider
  • Power System Studies Services Consultant And Service Provider
  • Power System Studies Services Consultant And Service Provider
Power System Studies Services Consultant And Service Provider
Get Best Quote

Power System Studies Services Consultant And Service Provider

Approx. Price: Rs 1 / UnitGet Latest Price
Product Details:
Business / Industry TypeIndustrial
LocationMaharashtra
Duration2-5 days
Service ModeOffline
Type Of Service ProviderCompany
Mode Of ServiceOffline

Power System Studies , Experts and Consultants :We are the Service Provider and Experts in Power System Studies, Power Quality Analysis Service Providers, Motor Starting Study And Analysis, Relay Coordination Study & Analysis, Short Circuit Study & Analysis, ARC Flash Study, Harmonic Study & Analysis, Voltage Drop Study & Analysis And Transient Stability Study. Reliserv Solution is the leading company carrying out Power Quality Analysis. If you are facing any problem related to power quality or want annual power audit we are here. Equipped with best Instrument in the world we carry out Power Quality and Harmonic Analysis. We can measure transient, swells, dip etc very easily. Our team of expertise consist of engineer with expertise of over 40 years which analyse the data of the Power Analyzer and give you the best solution for the problem being faced by you. These are the below Studies what we can Offer. 

1.Unbalanced Load Flow Study

2.Voltage Drop Study & Analysis
3. ELECTRICAL SWITCHGEAR RISK ASSESSMENT STUDY AND HAZARD ANALYSIS SERVICE
4. Motor Starting Study and Analysis
5. ENERGY AUDITING SERVICE
6. POWER QUALITY ANALYSIS
7.Power System Analysis
8.Load Flow Study
9.Relay Coordination Study & Analysis
10.Short Circuit Study & Analysis
11.Arc Flash Study
12.Harmonic Study & Analysis
13.Voltage Imbalance Study
14. FREQUENCY STABILITY ANALYSIS
15. VIBRATION STUDY AND ANALYSIS

 




Yes! I am Interested
Request CallBack
Load Flow Study
Ask For Price

Load Flow Study

Product Price : Get Latest Price
Product Details:
Duration2-5 days
Service ModeOffline
LocationMaharashtra

Load flow studies will be carried out with the Plant operating at normal/worst and rated load operating conditions. Load studies for all conditions of operation will be carried out based upon anticipated demand (load schedule) of the Peak Valley of low voltage high voltage Bus systems.

 

The following output data will be presented as a minimum for all load flow studies

  • Busbar voltages in terms of per unit of busbar rated voltage and phase.
  • Real and reactive components of power flow past a point in the system, i.e. Busbar and feeder in MW and Mvar.
  • MW and Mvar losses at the optimum transformer tap settings. The optimum tap setting being that which ensures at minimum load and full load, the voltage remains within specified tolerance limits (+/- 5% of the rated busbar voltage).
  • Loading of all the branches (transformers, cables etc.) in terms of % of their rated capabilities.
  • Total system demand, losses, and loading of the network in MW and Mvar.
  • Power factor at each busbar.
  • Voltage drop in feeder circuit cables.

Yes! I am Interested
Request CallBack
  • System Harmonics Study
  • System Harmonics Study
System Harmonics Study
Ask For Price

System Harmonics Study

Product Price : Get Latest Price
Product Details:
LocationMaharashtra
Duration2-5 days
Service ModeOffline
Studies will be carried out which simulates resonance and harmonic distortion in the plant. Harmonic current and voltage sources are to be defined at multiple locations in the power system. Capacitor banks, single tune filters and high pass filters included in the voltage and current distortion evaluation, impedance resonance scans, and in harmonic load flow results. The power distribution system will be examined prior to construction and the harmonic effect addressed during the design with the use of corrective filter designs evaluated prior to installation. All major buses and branches will be evaluated for harmonic content and for resonant impedance characteristics.

Yes! I am Interested
Save time! Get the Best Deal

*Your information is safe with us.

Request CallBack
Relay Coordination Study
Ask For Price

Relay Coordination Study

Product Price : Get Latest Price
Product Details:
LocationMaharashtra
Duration2-5 days
Service ModeOffline

Studies will be carried out which demonstrate co-ordination and discrimination of protective devices in such a manner that a fault appearing at a given point in the system is cleared by the protective device immediately upstream of the fault and by that device alone. Circuit Breakers upstream of the operated protective device will not be tripped.

Maximum and minimum symmetrical short circuit currents at each busbar and feeder line will be used in establishing settings for protective relays and devices.

Yes! I am Interested
Request CallBack
System Transient Stability Analysis Motor Starting
Ask For Price

System Transient Stability Analysis Motor Starting

Product Price : Get Latest Price
Product Details:
TechniqueMaharashtra
Service ModeOffline
Duration2-5 days

The following studies will be carried out under the system conditions stated :-

  • Stability power system and captive generators with a fault on each bus bar.
  • Voltage variations at busbars for drives start up of the largest rated motor with all other drives at standstill (static).
  • Voltage variations at busbars for drives start up the largest rated motor with all other drives running (dynamic).
  • Motor Reacceleration study.
  • Determination of tap settings for the transformers.
  • Load acceptance of the small Generator.
  • Suitability of starting of largest motor for different modes of operations.
  • Response of Power System and generators including frequency variation, voltage variation due to outage of any of the operating generator with normal connected load on the system.
  • The dynamic performance of the system with respect to the following minimum disturbances will be studied.
  • External Faults
  • Internal Faults
  • Load Throw off conditions
  • Performance of generators with without Grid.
  • Dynamic behaviour of Turbo Generators (including generators) in terms of Load Flows Load Sharing during Islanded condition. Internal external disturbances will be reported to establish critical clearing time and set protections accordingly, in case of fault, to avoid tripping of Generators.
  • Load-shedding scheme
  • Appropriate load shedding scheme will be suggested based on the criticality of loads.
  • Islanding scheme to save captive generation during grid disturbance will be suggested. The dynamics of the system will be studied with respect to grid disturbances and the settings of the frequency, voltage relays will be provided .

Yes! I am Interested
Request CallBack
Short Circuit Study
Ask For Price

Short Circuit Study

Product Price : Get Latest Price
Product Details:
LocationMaharashtra
Duration2-5 days
Service ModeOffline

The following types of fault will be simulated:

  • Three phase symmetrical fault
  • Line to Line fault
  • Line to Earth fault
  • Line to line to Earth fault

The following output data will be presented as a minimum for all short circuit fault studies:

  • Initial symmetrical fault current (l”k)
  • Peak asymmetric fault current (lp)
  • Symmetrical breaking current (lb)
  • Steady state short circuit current (lk)
  • Percentage dc component (ldc) (only presented for balanced 3-phase faults)

Short circuit currents on each busbar and line will be used to establish the interrupting and momentary ratings of circuit breakers, MCCBS, fuses and other switching devices at busbars and feeders.