Brand | SIEMENS , Schneider , ABB |
Usage/Application | Substation Automation Solutions for Chemical Industries |
Model Name/Number | SCADA |
Engineering Solutions: | Auto Transfer Scheme for Incomer and DG switchover |
Work | Load Shedding scheme |
Feature | Protection System Upgradation/ Retrofits with Modern Numerical Relays |
We offer Substation Automation Solutions for Chemical Industries for boosting the efficiency of operations and avoiding unnecessary breakdowns. We also provide training in our new installation for operation and maintenance staff of client to better understanding technology, thus increasing the plant efficiency.
Our Substation Automation Solutions for Chemical Industries are as follows:
Engineering Solutions:
A bus transfer system is designed to provide process continuity to the loads attached to a motor bus while transferring the bus from one source to another. A successful bus transfer under contingent conditions provides immense value and benefits to continuous process operations that cannot afford an interruption of power supply to plant auxiliaries.
We are experienced in designing and implementing such schemes for substations. This can be done as a retrofit in existing panels or supplied as a new panel as per station condition and requirement.
During overloads in the mains, the load shedding applied to interruptible loads is often the only solution to keep the industries in operation. Normally, in such cases, non-critical loads that are earlier identified are tripped automatically to avoid interruption of critical loads and induced penalties when power is being drawn from the grid.
We offer a range of products and solutions from Siemens/Schneider for these critical operations based on Current, Power or frequency for load shedding.
Relay coordination study and analysis is performed to make sure that safety operation of the system are functioning correctly and to avoid the nuisance tripping, as protection is a major concern in any industry and they rely on protective devices for the same.
The aim of a coordination study is to determine the characteristics, ratings, and settings of overcurrent protective devices which will ensure that minimum unfaulty load is interrupted when protective devices isolate a fault or overload anywhere in the system.
Older relay usually outdated, are supposed to be replaced in industries to avoid mal tripping and ease operations in a plant. We offer
Our team is experienced in carrying out such services in all types of industries, from data collection, to upgradation and handing over.
Outages can cause losses in an industry. These outages are often classified as Controlled outage (normal shutdown) or uncontrolled outage (fault trip). Our meters are specifically designed to register such outages in Minutes or seconds and report to automation system. This helps in evaluation of losses on per day, per month or per year basis.
Brand | SIEMENS , Schneider , Pheonix |
Model Name/Number | SCADA |
Usage/Application | Industrial |
Mounting Type | Panel |
Capacity | As per requirement |
Available For | Automation Applications |
We provide Substation Automation system SCADA , SAS solutions with modern state-of-art .technologies comprising of various communication protocols. e.g. IEC61850. 1.101, IEC103. IEC104,Modbus. Modbus TCP/IP. OPC etc. System Architecture-Substation Automation.
We offer the design, engineering development of PC & Operator Panel based HMI & SCADA solutions for Substations. Switchyards, Power & Process plants.
Services Offered
• Monitoring & Control of Existing substation by collecting Input, output, Analog data points from the field via RTU / Gateway.
• Establishing Control & monitoring of various main station & substation from the centralized location to improve the quality & stability of the power system.
• Existing old station getting upgraded by installation of RTU, Local monitoring system. DCPS & Battery for the new RTU panels.
• Interconnecting Field signals with RTU & transmitting the same to Master control center New SCADA system getting online.
• Preparation of engineering documents such as SLD. control room Layout, BOM and I/O List, cable schedule and adaptation schedule, as-built drawings in PDF / CAD format.
• Panel Erection, Cable laying and Termination for existing sub-station and new sub-stations.
• Configuration, Testing and commissioning of RTU and obtaining SAT certificate from customer.
Supervisory Control and Data Acquisition (SCADA):
It is a control system architecture comprising computers, networked data communications and graphical user interfaces (GUI) for high-level process supervisory management
We have the control room for controlling the field devices integrated with RTU and control panel.
List of the devices and Panel in the Control centre are specified below:
1. Siemens RTU with two control relay panels adjacent to it.
2. One is CRP panel- ON load Tap changer
3. The other panel is the RTCC remote tap changer.4. Siemens SCADA with an operating console.
Training Session on Scada System:
We provide the training session for how to do the Configurations of field devices Input/ Output and Operate and Monitoring of Scada
We have the control center room which control and monitor the field devices and do the operation from remote location
Analyzing and optimizing the system using SIEMENS Scada.
· Basic concepts of SCADA
· SCADA application and project
· SCADA and networking
· Creating and accessing real-time and historic trends
· Interfacing SCADA via Excel, via PLC, via Relay, via Motor/LED
· Troubleshooting the application
Application Type | Industrial |
No Of Persons To Be Managed | As per the requirement |
Requirement Details | SCADA Solutions |
Service Duration | As per the project requirement |
Type | Automation/Scada Solutions & Services |
Remote Control | YES |
We are the leading Service Providers for Automation/Scada solutions & their testing.
It’s Time to Transform Your Projects and Operations:
Many of the industry’s standard approaches were created decades ago, long before today’s innovation. Doing more of the same is yielding only incremental benefits and management expects you to deliver better results. With a partner like Siemens/ABB/ALSTOM, you can. Our automation expertise – from projects to operations – is focused on helping you hit your targets and move your organization into Top Quartile performance.
You need a partner with the expertise and track record to deliver predictable success.
We’re ready to put our industry-tailored experience and solutions to work for you.
Automation/Scada solutions ApplicationsIndustries like Power Generation:Power Generation:-
Today’s operational realities are making it more difficult to achieve your business objectives.
As a power producer, you’re facing dynamic times. Renewables, plant cycling, regulatory compliance and an evolving workforce are all making it more difficult for you to achieve your business objectives. It’s because of these challenges that more and more power producers are turning to Siemens/ABB/Alstom. Our team of power industry experts work with you to enhance your operational readiness – improving plant availability and flexibility while also enhancing workforce proficiency and productivity.
Industrial Energy
Enhance Your Profitability Through Better Industrial Energy And Utility PerformanceStable utility operations are needed to support all production. Energy is a large part of your operating costs and emissions constraints are increasing. With Emerson’s help you can make utility performance reliable and responsive, improve efficiency, maximize low cost fuel use, and lower emissions… all at the same time.
SUBSTATION CONTROLLERS & SWITCHESwe offer an industry-leading suite of substation controllers and switches that support a variety of substation control, communication, monitoring, protection and automation applications and functions.
SAS to utilities Relay,Mfm,IEC-104/101/103/61850 & Modbus.Reliable transmission and distribution of electricity is the key to a Smart Grid and an integral requirement for Utilities. Substation Automation Systems (SAS) as a comprehensive part of substation control and monitoring solution provides functions such as advanced power system management and monitoring of the condition of the equipment while as service.
Power, a non-renewable source of energy is one of the most focused industries today. For systematic power distribution, power has to be healthy. At every substation level the parameters are checked to determine the condition of power. These parameters go through different stages of checking, rectifying, controlling, etc which are performed at substation level. To integrate all these functions in a system & to perform simultaneous checks, substation automation systems are brought in concept.
We are the leading enablers of substation automation solutions including IEC 61850 /104 /101 /103/61850 & Modbus. Our substation automation offerings comply with IEC 61850 standard,, ensuring key to protection, control, automation, monitoring and real-time communications capabilities of substations with existing legacy as well as systems for future. Our smart automation reduces operational and maintenance costs, thereby increasing the performance of the plant and improving the efficiency in operations.
*Your information is safe with us.
Technology | SCADA |
Service Charges | As per client requirement |
Scope | Retrofitting Scada/RTU/Gateway and Energy management & load shedding |
Work | integrated Electrical & Automation solutions for Oil & Gas, Cement, Metal and other Manufacturing in |
Feature | Integration of protection IED's with RS-485 communication (IEC 60870-5-103) |
Feature 1 | Integration of Master SCADA and operation from Master SCADA |
We offer Retrofitting Scada/ RTU/Gateway solutions, an industry-leading suite of substation controllers and switches that support a variety of substation control, communication, monitoring, protection and automation applications and functions.
Integration of protection IED‘s with RS-485 communication (IEC 60870-5-103)
Ethernet Switch for the IEC 60870-5-104 communication to the control system
Binary input card for common alarms
Option: Remote control and status supervision of the primary equipment with digital I/O modules.
We offer integrated Electrical & Automation solutions for Oil & Gas, Cement, Metal and other Manufacturing industries, Infrastructure as well as utilities like Power and Water. We have experience of over four decades in diverse segments and proven capabilities across the entire value chain – comprising Proposals, Design, Engineering, Project Planning, Integration, Software Development, Integrated testing / FAT, Commissioning / SAT and After-Sales Service.
Integration of Master SCADA and operation from Master SCADA. The process involves :
We are committed to providing fast, courteous and professional post-sales technical support, product upgrades, and testing and repair services to our customers. Technical support engineers and technical specialists are standing by to assist you with your protection and control and substation automation product questions.
Energy management & load shedding.SCADA and Energy Management Solution
Our SCADA and Energy Management Solution package is a very cost-effective solution to monitor and control your application.
Our Intelligent and advanced system provides complete solution for monitoring and management of energy in the industrial plants along with control and automation. All the required hardware and software for monitoring of energy are part of the system.
The complete systems can be installed and configured based on user and application requirements. Multiple verticals like electric automation, process control, BMS, Fire & Safety along with Security can be integrated. Our solutions are well known for Oil & Gas, Power Transmission & Distribution, Alternative Energy Markets etc.
Technology | SCADA |
Service Charges | As per client requirement |
Engineering Solutions: | Auto Transfer Scheme for Incomer and DG switchover |
Work | Load Shedding scheme |
Feature | Power System Studies and Relay Coordination |
Scope of the study | Protection System Upgradation/ Retrofits with Modern Numerical Relays |
We offer Substation Automation Solutions for Garments Industries for Industries for boosting the efficiency of operations and avoiding unnecessary breakdowns. We also provide training in our new installation for operation and maintenance staff of client to better understanding technology, thus increasing the plant efficiency.
Our Substation Automation Solutions for Garments industries are as follows:
Engineering Solutions:
A bus transfer system is designed to provide process continuity to the loads attached to a motor bus while transferring the bus from one source to another. A successful bus transfer under contingent conditions provides immense value and benefits to continuous process operations that cannot afford an interruption of power supply to plant auxiliaries.
We are experienced in designing and implementing such schemes for substations. This can be done as a retrofit in existing panels or supplied as a new panel as per station condition and requirement.
During overloads in the mains, the load shedding applied to interruptible loads is often the only solution to keep the industries in operation. Normally, in such cases, non-critical loads that are earlier identified are tripped automatically to avoid interruption of critical loads and induced penalties when power is being drawn from the grid.
We offer a range of products and solutions from Siemens/Schneider for these critical operations based on Current, Power or frequency for load shedding.
Relay coordination study and analysis is performed to make sure that safety operation of the system are functioning correctly and to avoid the nuisance tripping, as protection is a major concern in any industry and they rely on protective devices for the same.
The aim of a coordination study is to determine the characteristics, ratings, and settings of overcurrent protective devices which will ensure that minimum unfaulty load is interrupted when protective devices isolate a fault or overload anywhere in the system.
Older relay usually outdated, are supposed to be replaced in industries to avoid mal tripping and ease operations in a plant. We offer
Our team is experienced in carrying out such services in all types of industries, from data collection, to upgradation and handing over.
Outages can cause losses in an industry. These outages are often classified as Controlled outage (normal shutdown) or uncontrolled outage (fault trip). Our meters are specifically designed to register such outages in Minutes or seconds and report to automation system. This helps in evaluation of losses on per day, per month or per year basis.
Technology | SCADA |
Service Charges | As per client requirement |
Scope | Engineering Solutions |
Work | Load Shedding scheme |
Feature | Power System Studies and Relay Coordination |
Feature 1 | Outage Loss Monitoring meters |
We offer Substation Automation Solutions for Pharma Industries for boosting the efficiency of operations and avoiding unnecessary breakdowns. We also provide training in our new installation for operation and maintenance staff of client to better understanding technology, thus increasing the plant efficiency.
Our Substation Automation Solutions for Pharma industries are as follows:
Engineering Solutions:
A bus transfer system is designed to provide process continuity to the loads attached to a motor bus while transferring the bus from one source to another. A successful bus transfer under contingent conditions provides immense value and benefits to continuous process operations that cannot afford an interruption of power supply to plant auxiliaries.
We are experienced in designing and implementing such schemes for substations. This can be done as a retrofit in existing panels or supplied as a new panel as per station condition and requirement.
During overloads in the mains, the load shedding applied to interruptible loads is often the only solution to keep the industries in operation. Normally, in such cases, non-critical loads that are earlier identified are tripped automatically to avoid interruption of critical loads and induced penalties when power is being drawn from the grid.
We offer a range of products and solutions from Siemens/Schneider for these critical operations based on Current, Power or frequency for load shedding.
Relay coordination study and analysis is performed to make sure that safety operation of the system are functioning correctly and to avoid the nuisance tripping, as protection is a major concern in any industry and they rely on protective devices for the same.
The aim of a coordination study is to determine the characteristics, ratings, and settings of overcurrent protective devices which will ensure that minimum unfaulty load is interrupted when protective devices isolate a fault or overload anywhere in the system.
Older relay usually outdated, are supposed to be replaced in industries to avoid mal tripping and ease operations in a plant. We offer
Our team is experienced in carrying out such services in all types of industries, from data collection, to upgradation and handing over.
Outages can cause losses in an industry. These outages are often classified as Controlled outage (normal shutdown) or uncontrolled outage (fault trip). Our meters are specifically designed to register such outages in Minutes or seconds and report to automation system. This helps in evaluation of losses on per day, per month or per year basis.
*Your information is safe with us.
Technology | SCADA |
Service Charges | As per client requirement |
Scope | Substation Automation Solutions for RMG Industries |
Engineering Solutions | Auto Transfer Scheme for Incomer and DG switchover |
Feature | Load Shedding scheme |
Feature 3 | Power System Studies and Relay Coordination's |
We offer Substation Automation for RMG Industries for boosting the efficiency of operations and avoiding unnecessary breakdowns. We also provide training in our new installation for operation and maintenance staff of client to better understanding technology, thus increasing the plant efficiency.
Substation Automation for RMG Industries solutions are as follows:
Engineering Solutions:
A bus transfer system is designed to provide process continuity to the loads attached to a motor bus while transferring the bus from one source to another. A successful bus transfer under contingent conditions provides immense value and benefits to continuous process operations that cannot afford an interruption of power supply to plant auxiliaries.
We are experienced in designing and implementing such schemes for substations. This can be done as a retrofit in existing panels or supplied as a new panel as per station condition and requirement.
During overloads in the mains, the load shedding applied to interruptible loads is often the only solution to keep the industries in operation. Normally, in such cases, non-critical loads that are earlier identified are tripped automatically to avoid interruption of critical loads and induced penalties when power is being drawn from the grid.
We offer a range of products and solutions from Siemens/Schneider for these critical operations based on Current, Power or frequency for load shedding.
Relay coordination study and analysis is performed to make sure that safety operation of the system are functioning correctly and to avoid the nuisance tripping, as protection is a major concern in any industry and they rely on protective devices for the same.
The aim of a coordination study is to determine the characteristics, ratings, and settings of overcurrent protective devices which will ensure that minimum unfaulty load is interrupted when protective devices isolate a fault or overload anywhere in the system.
Older relay usually outdated, are supposed to be replaced in industries to avoid mal tripping and ease operations in a plant. We offer
Our team is experienced in carrying out such services in all types of industries, from data collection, to upgradation and handing over.
Outages can cause losses in an industry. These outages are often classified as Controlled outage (normal shutdown) or uncontrolled outage (fault trip). Our meters are specifically designed to register such outages in Minutes or seconds and report to automation system. This helps in evaluation of losses on per day, per month or per year basis.
Application Type | Industrial |
No Of Persons To Be Managed | As per the requirement |
Service Duration | As per the project requirement |
Usage/Application | Substation Automation Solutions for Steel Plants |
Type | Automation/Scada Solutions & Services |
Remote Control | YES |
We offer Automation Solutions for Steel Plants for boosting the efficiency of operations and avoiding unnecessary breakdowns. We also provide training in our new installation for operation and maintenance staff of client to better understanding technology, thus increasing the plant efficiency.
Our Automation Solutions for Steel Plants are as follows:
Engineering Solutions:
A bus transfer system is designed to provide process continuity to the loads attached to a motor bus while transferring the bus from one source to another. A successful bus transfer under contingent conditions provides immense value and benefits to continuous process operations that cannot afford an interruption of power supply to plant auxiliaries.
We are experienced in designing and implementing such schemes for substations. This can be done as a retrofit in existing panels or supplied as a new panel as per station condition and requirement.
During overloads in the mains, the load shedding applied to interruptible loads is often the only solution to keep the industries in operation. Normally, in such cases, non-critical loads that are earlier identified are tripped automatically to avoid interruption of critical loads and induced penalties when power is being drawn from the grid.
We offer a range of products and solutions from Siemens/Schneider for these critical operations based on Current, Power or frequency for load shedding.
Relay coordination study and analysis is performed to make sure that safety operation of the system are functioning correctly and to avoid the nuisance tripping, as protection is a major concern in any industry and they rely on protective devices for the same.
The aim of a coordination study is to determine the characteristics, ratings, and settings of overcurrent protective devices which will ensure that minimum unfaulty load is interrupted when protective devices isolate a fault or overload anywhere in the system.
Older relay usually outdated, are supposed to be replaced in industries to avoid mal tripping and ease operations in a plant. We offer
Our team is experienced in carrying out such services in all types of industries, from data collection, to upgradation and handing over.
Outages can cause losses in an industry. These outages are often classified as Controlled outage (normal shutdown) or uncontrolled outage (fault trip). Our meters are specifically designed to register such outages in Minutes or seconds and report to automation system. This helps in evaluation of losses on per day, per month or per year basis.